US$1.00 | 1,000 Meters (MOQ) |
Code | Phase Conductor | Bare Neutral Messenger | Weight Per | Rating(Amps) | ||||||
Name | 1000 ft(lbs) | |||||||||
Size | Strand | Insulation | Size | *Strand | Breaking | XLP | POLY | XLP | POLY | |
AWG | thickness | AWG | strength | |||||||
(MLS) | (lbs) | |||||||||
AAC | ||||||||||
Pekingese | 6 | solid | 45 | 6 | 7/w | 563 | 63.5 | 61.7 | 70 | 70 |
Collie | 6 | 7/w | 45 | 6 | 7/w | 563 | 66.8 | 63.1 | 70 | 70 |
Dachshund | 4 | solid | 45 | 4 | 7/w | 881 | 95.5 | 93.4 | 90 | 90 |
Spaniel | 4 | 7/w | 45 | 4 | 7/w | 881 | 101 | 95.4 | 90 | 90 |
Doberman | 2 | 7/w | 45 | 2 | 7/w | 1,350 | 153 | 145.7 | 120 | 120 |
Malemute | 1/0 | 19/w | 60 | 1/0 | 7/w | 1,990 | 243 | 234.2 | 160 | 160 |
ACSR NEUTRAL-MESSENGER | ||||||||||
Setter | 6 | solid | 45 | 6 | '6/1 | 1.19 | 75 | 73.2 | 70 | 70 |
Shepherd | 6 | 7/w | 45 | 6 | '6/2 | 1.19 | 78.3 | 74.6 | 70 | 70 |
Eskimo | 4 | solid | 45 | 4 | '6/3 | 1.86 | 114 | 111.6 | 90 | 90 |
Terrier | 4 | 7/w | 45 | 4 | '6/4 | 1.86 | 119 | 113.6 | 90 | 90 |
Chow | 2 | 7/w | 45 | 2 | '6/5 | 2.85 | 182 | 174.7 | 120 | 120 |
Bull | 1/0 | 19/w | 60 | 1/0 | '6/6 | 4.38 | 289 | 280.3 | 160 | 160 |
6201 ALLOY NEUTRAL-MESSENGER | ||||||||||
Chihuahua | 6 | solid | 45 | 6 | 7/w | 1,110 | 67.6 | 65.8 | 70 | 70 |
Vizsla | 6 | 7/w | 45 | 6 | 7/w | 1,110 | 70.9 | 67.2 | 70 | 70 |
Harrier | 4 | solid | 45 | 4 | 7/w | 1,760 | 102 | 99.9 | 90 | 90 |
Whippet | 4 | 7/w | 45 | 4 | 7/w | 1,760 | 107 | 101.9 | 90 | 90 |
Schnauzer | 2 | 7/w | 45 | 2 | 7/w | 2,800 | 163 | 156.2 | 120 | 120 |
Heeler | 1/0 | 19/w | 60 | 1/0 | 7/w | 4,460 | 259 | 250.8 | 160 | 160 |
Code | Phase Conductor | Bare Neutral Messenger | Weight Per | Ampacity (Amps) | |||||||
Name | 1000 ft(lbs) | ||||||||||
Size | Stranding | Insulation | Size | Stranding | Breaking | XLP | POLY | XLP | POLY | ||
AWG | thickness | AWG | strength | ||||||||
(MLS) | (lbs) | ||||||||||
6201 ALLOY NEUTRAL-MESSENGER | |||||||||||
Minex | 6 | solid | 45 | 6 | 7 | 1,110 | 106.6 | 102.9 | 85 | 70 | |
Hippa | 6 | 7/w | 45 | 6 | 7 | 1,110 | 113.2 | 105.7 | 85 | 70 | |
Prawn | 4 | solid | 45 | 4 | 7 | 1,760 | 158.4 | 154.1 | 115 | 90 | |
Barnacles | 4 | 7/w | 45 | 4 | 7 | 1,760 | 168.3 | 158.2 | 115 | 90 | |
Shrimp | 2 | 7/w | 45 | 2 | 7 | 2,800 | 253.7 | 239.7 | 150 | 120 | |
Gammarus | 1/0 | 7/w | 60 | 1/0 | 7 | 4,460 | 411.7 | 386 | 205 | 160 | |
Leda | 1/0 | 19/w | 60 | 1/0 | 7 | 4,460 | 402.7 | 386 | 205 | 160 | |
Dungenese | 2/0 | 7/w | 60 | 2/0 | 7 | 5,390 | 506.8 | 476.3 | 235 | 185 | |
Cyclops | 2/0 | 19/w | 60 | 2/0 | 7 | 5,390 | 495.3 | 476.3 | 235 | 185 | |
Flustra | 3/0 | 19/w | 60 | 3/0 | 7 | 6,790 | 611.4 | 589.1 | 275 | 215 | |
Lepas | 4/0 | 19/w | 60 | 4/0 | 7 | 8,560 | 757.1 | 730.5 | 315 | 245 | |
6201 ALLOY REDUCED NEUTRAL-MESSENGER | |||||||||||
Artemia | 4 | solid | 45 | 6 | 7 | 1,110 | 141.4 | 137.1 | 115 | 90 | |
Crab | 4 | 7/w | 45 | 6 | 7 | 1,110 | 151.3 | 141.2 | 115 | 90 | |
Solaster | 2 | 7/w | 45 | 4 | 7 | 1,760 | 226.6 | 212.6 | 150 | 120 | |
Sandcrab | 1/0 | 7/w | 60 | 2 | 7 | 2,800 | 368.8 | 343.1 | 205 | 160 | |
Echinus | 1/0 | 19/w | 60 | 2 | 7 | 2,800 | 358.8 | 343.1 | 205 | 160 | |
Crayfish | 2/0 | 7/w | 60 | 1 | 7 | 3,530 | 452.6 | 422.5 | 235 | 185 | |
Sipho | 2/0 | 19/w | 60 | 1 | 7 | 3,530 | 441 | 422.5 | 235 | 185 | |
Fulgar | 3/0 | 19/w | 60 | 1/0 | 7 | 4,460 | 543.4 | 521.1 | 275 | 215 | |
Arca | 4/0 | 19/w | 60 | 2/0 | 7 | 5,390 | 671.2 | 644.6 | 315 | 245 | |
AAC NEUTRAL-MESSENGER | |||||||||||
Haiotis | 6 | solid | 45 | 6 | 7 | 563 | 102.5 | 98.8 | 85 | 70 | |
Patella | 6 | 7/w | 45 | 6 | 7 | 563 | 109.1 | 101.6 | 85 | 70 | |
Fusus | 4 | solid | 45 | 4 | 7 | 881 | 151.9 | 147.6 | 115 | 90 | |
Oyster | 4 | 7/w | 45 | 4 | 7 | 881 | 161.8 | 151.7 | 115 | 90 | |
Clam | 2 | 7/w | 45 | 2 | 7 | 1,350 | 243.2 | 229.2 | 150 | 120 | |
Murex | 1/0 | 7/w | 60 | 1/0 | 7 | 1,990 | 395.1 | 369.4 | 205 | 160 | |
Purpura | 1/0 | 19/w | 60 | 1/0 | 7 | 1,990 | 386.1 | 369.4 | 205 | 160 | |
Nassa | 2/0 | 7/w | 60 | 2/0 | 7 | 2,510 | 485.8 | 455.3 | 235 | 185 | |
Melita | 3/0 | 19/w | 60 | 3/0 | 19 | 3,310 | 585.2 | 562.9 | 275 | 215 | |
Portunus | 4/0 | 19/w | 60 | 4/0 | 19 | 4,020 | 723.9 | 697.3 | 315 | 245 | |
Nannynose | 336.4 | 19/w | 80 | 336 | 19 | 6,146 | 1160 | 1118 | 420 | 325 | |
WITH FULL SIZE ACSR MESSENGER | |||||||||||
Paludina | 6 | solid | 45 | 6 | '6/1 | 1,190 | 114 | 113 | 85 | 70 | |
Voluta | 6 | 7/w | 45 | 6 | '6/1 | 1,190 | 120 | 113 | 85 | 70 | |
Whelk | 4 | solid | 45 | 4 | '6/1 | 1,860 | 169 | 165 | 115 | 90 | |
Periwinkle | 4 | 7/w | 45 | 4 | '6/1 | 1,860 | 176 | 172 | 115 | 90 | |
Conch | 2 | 7/w | 45 | 2 | '6/1 | 2,850 | 267 | 261 | 150 | 120 | |
Neritina | 1/0 | 7/w | 60 | 1/0 | '6/1 | 4,380 | 530 | 419 | 205 | 160 | |
Cenia | 1/0 | 19/w | 60 | 1/0 | '6/1 | 4,380 | 426 | 416 | 205 | 160 | |
Runcina | 2/0 | 7/w | 60 | 2/0 | '6/1 | 5,310 | 530 | 519 | 235 | 185 | |
Triton | 2/0 | 19/w | 60 | 2/0 | '6/1 | 5,310 | 526 | 514 | 235 | 185 | |
Cherrystone | 3/0 | 7/w | 60 | 3/0 | '6/1 | 6,620 | 656 | 643 | 250 | 200 | |
Mursia | 3/0 | 19/w | 60 | 3/0 | '6/1 | 6,620 | 650 | 638 | 250 | 200 | |
Razor | 4/0 | 7/w | 60 | 4/0 | '6/1 | 8,350 | 814 | 799 | 315 | 245 | |
Zuzara | 4/0 | 19/w | 60 | 4/0 | '6/1 | 8,350 | 805 | 792 | 315 | 245 | |
Limpet | 336.4 | 19/w | 80 | 336 | '6/1 | 8,680 | 1209 | 1167 | 420 | 325 | |
WITH ACSR REDUCED SIZE MESSENGER | |||||||||||
Scallop | 4 | Solid | 45 | 6 | '6/1 | 1,190 | 148 | 144 | 115 | 90 | |
Strombus | 4 | 7/w | 45 | 6 | '6/1 | 1,190 | 158 | 148 | 115 | 90 | |
Cockle | 2 | 7/ w | 45 | 4 | '6/1 | 1,860 | 233 | 227 | 150 | 120 | |
Janthina | 1/0 | 7/ w | 60 | 2 | '6/1 | 2,850 | 376 | 365 | 205 | 160 | |
Ranella | 1/0 | 19/ w | 60 | 2 | '6/1 | 2,850 | 372 | 362 | 205 | 160 |
Code | Phase Conductor | Bare Neutral Messenger | Weight Per | Rating(Amps) | ||||||
Name | 1000 ft(lbs) | |||||||||
Size | Strand | Insulation | Size | Strand | Breaking | XLP | POLY | XLP | POLY | |
AWG | thickness | AWG | strength | |||||||
(MLS) | (lbs) | |||||||||
AAC NEUTRAL-MESSENGER | ||||||||||
Clydesdale | 4 | Solid | 45 | 4 | 7 | 881 | 208 | 201.8 | 100 | 80 |
Pinto | 4 | 7/w | 45 | 4 | 7 | 881 | 223 | 207.9 | 100 | 80 |
Mustang | 2 | 7/w | 45 | 2 | 7 | 1,350 | 333 | 312.6 | 135 | 105 |
Criollo | 1/0 | 19/w | 60 | 1/0 | 7 | 1,990 | 529 | 504.5 | 180 | 140 |
Percheron | 2/0 | 19/w | 60 | 2/0 | 7 | 2,510 | 649 | 620.5 | 205 | 160 |
Hanoverian | 3/0 | 19/w | 60 | 3/0 | 19 | 3,310 | 799 | 765.6 | 235 | 185 |
Oldenburg | 4/0 | 19/w | 60 | 4/0 | 19 | 4,020 | 986 | 946.7 | 275 | 210 |
Lippizaner | 336.4 | 19/w | 80 | 336.4 | 19 | 6,146 | 1,546 | 1,519.20 | 370 | 280 |
ACSR NEUTRAL-MESSNGER | ||||||||||
Morochuca | 6 | Solid | 45 | 6 | '6/1 | 1,190 | 152 | 147.4 | 75 | 60 |
Chola | 6 | 7/w | 45 | 6 | '6/1 | 1,190 | 162 | 151.7 | 75 | 60 |
Morgan | 4 | Solid | 45 | 4 | '6/1 | 1,860 | 226 | 220 | 100 | 80 |
Hackney | 4 | 7/w | 45 | 4 | '6/1 | 1,860 | 241 | 226.1 | 100 | 80 |
Palomino | 2 | 7/w | 45 | 2 | '6/1 | 2,850 | 362 | 342.6 | 135 | 105 |
Costena | 1/0 | 19/w | 60 | 1/0 | '6/1 | 4,380 | 575 | 550.6 | 180 | 140 |
Grullo | 2/0 | 19/w | 60 | 2/0 | '6/1 | 5,310 | 707 | 678.7 | 205 | 160 |
Suffolk | 3/0 | 19/w | 60 | 3/0 | '6/1 | 6,620 | 872 | 838.9 | 235 | 185 |
Appaloosa | 4/0 | 19/w | 60 | 4/0 | '6/1 | 8,350 | 1079 | 1039.2 | 275 | 210 |
Bronco | 336.4 | 19/w | 80 | 336.4 | '18/1 | 8,580 | 1613 | 1568.2 | 370 | 280 |
Gelding | 336.4 | 19/w | 80 | 4/0 | '6/1 | 8,350 | 1548 | 1494.3 | 370 | 280 |
6201 ALLOY NEUTRAL-MESSENGER | ||||||||||
Bay | 6 | Solid | 45 | 6 | 7 | 1,110 | 145 | 140 | 75 | 60 |
French Coach | 6 | 7/w | 45 | 6 | 7 | 1,110 | 155 | 144.3 | 75 | 60 |
German Coach | 4 | Solid | 45 | 4 | 7 | 1,760 | 214 | 208.3 | 100 | 80 |
Arabian | 4 | 7/w | 45 | 4 | 7 | 1,760 | 229 | 214.4 | 100 | 80 |
Belgian | 2 | 7/w | 45 | 2 | 7 | 2,800 | 344 | 323.1 | 135 | 105 |
Shetland | 1/0 | 19/w | 60 | 1/0 | 7 | 4,460 | 546 | 521.1 | 180 | 140 |
Thoroughbred | 2/0 | 19/w | 60 | 2/0 | 7 | 5,390 | 670 | 641.5 | 205 | 160 |
Trotter | 3/0 | 19/w | 60 | 3/0 | 7 | 6,790 | 825 | 791.8 | 235 | 185 |
Walking | 4/0 | 19/w | 60 | 4/0 | 7 | 8,560 | 1019 | 979.7 | 275 | 210 |
6201 ALLOY NEUTRAL-MESSENGER | ||||||||||
Code Name | Phase Conductor | Bare Neutral Messenger | Weight Per 1000ft(lbs) | Rating(Amps) | ||||||
Size AWG | Strand | Insulation Thickness(mls) | Size AWG | Strand | Breaking Strength(lbs) | XLPE | Poly | XLPE | Poly | |
Bay | 6 | Solid | 45 | 6 | 7 | 1,110 | 145 | 140.0 | 75 | 60 |
French Coach | 6 | 7/w | 45 | 6 | 7 | 1,110 | 155 | 144.3 | 75 | 60 |
German Coach | 4 | Solid | 45 | 4 | 7 | 1,760 | 214 | 208.3 | 100 | 80 |
Arabian | 4 | 7/w | 45 | 4 | 7 | 1,760 | 229 | 214.4 | 100 | 80 |
Belgian | 2 | 7/w | 45 | 2 | 7 | 2,800 | 344 | 323.1 | 135 | 105 |
Shetland | 1/0 | 19/w | 60 | 1/0 | 7 | 4,460 | 546 | 521.1 | 180 | 140 |
Thoroughbred | 2/0 | 19/w | 60 | 2/0 | 7 | 5,390 | 670 | 641.5 | 205 | 160 |
Trotter | 3/0 | 19/w | 60 | 3/0 | 7 | 6,790 | 825 | 791.8 | 235 | 185 |
Walking | 4/0 | 19/w | 60 | 4/0 | 7 | 8,560 | 1,019 | 979.7 | 275 | 210 |
Model | Name |
BV | Copper Core PVC Insulation Wire |
BLV | Aluminum Core PVC Insulation Wire |
BVR | Copper Core PVC Insulation Flexible Wire |
BVV | Copper Core PVC Insulation PVC Sheath Round Wire |
BVVB | Copper Core PVC Insulation PVC Sheath Flat Wire |
BLVVB | Aluminum Core PVC Insulation PVC Sheath Flat Wire |
BV-90 | Copper Core Heat-resistance 105oC PVC Insulation |
Nominal Section(mm²) | No./Dia. of Core (mm) | Max O.D(mm) | Reference Weight (kg/km) | Conductor Resistance at 20oC≤(Ω/km) |
0.5 | 1/0.80 | 2.4 | 8.5 | 36.0 |
0.75(A) | 1/0.97 | 2.6 | 11.1 | 24.5 |
0.75(B) | 7/0.37 | 2.8 | 12.0 | 24.5 |
1.0(A) | 1/1.13 | 2.8 | 13.9 | 18.1 |
1.0(B) | 7/0.43 | 3.0 | 15.0 | 18.1 |
Nominal Section(mm²) | No/Dia.of Core(mm) | Max O.D (mm) | Reference Weight(kg/km) | Conductor Resistance at 20oC≤(Ω/km) | ||
Copper | Aluminum | Aluminum | Copper | |||
1.5(A) | 1/1.38 | 3.3 | 20.3 | / | / | 12.1 |
1.5(B) | 7/0.52 | 3.5 | 21.6 | / | / | 12.1 |
2.5(A) | 1/1.78 | 3.9 | 31.6 | 17 | 11.8 | 7.41 |
2.5(B) | 7/0.68 | 4.2 | 34.8 | / | / | 7.41 |
4(A) | 1/2.55 | 4.4 | 47.1 | 22 | 7.39 | 4.61 |
4(B) | 7/0.85 | 4.8 | 50.3 | / | / | / |
6(A) | 7/0.85 | 4.8 | 50.3 | 29 | 4.91 | 3.08 |
6(B) | 7/1.04 | 5.4 | 71.2 | / | / | 3.08 |
10 | 7/1.35 | 7.0 | 119 | 62 | 3.08 | 1.83 |
16 | 7/1.70 | 8.0 | 179 | 78 | 1.91 | 1.15 |
25 | 27/2.04 | 10.0 | 281 | 118 | 1.20 | 0.727 |
35 | 27/2.52 | 11.5 | 381 | 156 | 0.868 | 0.524 |
50 | 19/1.78 | 13.0 | 521 | 215 | 0.641 | 0.387 |
70 | 19/2.14 | 15.0 | 734 | 282 | 0.443 | 0.268 |
95 | 19/2.52 | 17.5 | 962 | 385 | 0.320 | 0.193 |
120 | 37/2.03 | 19.0 | 1180 | 431 | 0.253 | 0.153 |
150 | 37/2.25 | 21.0 | 1470 | 539 | 0.206 | 0.124 |
185 | 37/2.52 | 23.5 | 1810 | 666 | 0.164 | 0.0991 |
240 | 61/2.25 | 26.5 | 2350 | 857 | 0.125 | 0.0754 |
300 | 61/2.52 | 29.5 | 2930 | 1070 | 0.100 | 0.0601 |
400 | 61/2.85 | 33.0 | 3870 | 1390 | 0.0778 | 0.0470 |
Nominal Section | Structure of Cores Core x No./Dia | Max Outer Dia (mm) | Reference Weight(kg/km) | Conductor Resistance at 20oC≤(Ω/km) | |||
(mm²) | (mm) | Aluminum | Copper | Copper | Aluminum | Copper | Aluminum |
2×0.75 | 2×1/0.97 | / | 4.6×7.0 | 43.7 | 24.5 | / | / |
2×1.0 | 2×1/1.13 | / | 4.8×7.4 | 51.0 | 18.1 | / | / |
2×1.5 | 2×1/1.38 | / | 5.4×8.4 | 65.9 | 12.1 | / | / |
2×2.5 | 2×1/1.78 | 6.2×9.8 | 6.2×9.8 | 95.7 | 64.9 | 7.41 | 11.8 |
2×4 | 2×7/0.85 | 6.8×11.0 | 7.2×11.5 | 146.0 | 80.7 | 4.61 | 7.39 |
2×6 | 2×7/1.04 | 7.4×12.0 | 8.0×13.0 | 200.0 | 104 | 3.08 | 4.91 |
2×10 | 2×7/1.35 | 9.6×16.0 | 9.6×16.0 | 323.0 | 177 | 1.83 | 3.08 |
3×0.75 | 3×1/0.97 | / | 4.6×9.4 | 62.6 | / | 24.5 | / |
3×1.0 | 3×1/1.13 | / | 4.8×9.8 | 74.3 | / | 18.10 | / |
3×1.5 | 3×1/1.38 | / | 5.4×11.5 | 95.6 | / | 12.10 | / |
3×2.5 | 3×1/1.78 | 6.2×13.5 | 6.2×13.5 | 140 | 93.9 | 7.41 | 11.8 |
3×4 | 3×7/0.85 | 7.0×15.0 | 7.4×16.5 | 220 | 123 | 7.41 | 7.39 |
3×6 | 3×7/1.04 | 7.4×17.0 | 8.0×18.0 | 295 | 153 | 4.61 | 4.91 |
3×10 | 3×7/0.35 | 9.6×22.5 | 9.6×22.5 | 485 | 261 | 1.83 | 3.08 |
Nominal Section(mm²) | Structure of Cores Core x No./Dia (mm) | Max Outer Dia(mm) | Reference Weight(kg/km) |
1×0.75 | 1×1/0.97 | 4.3 | 23 |
1×1.0 | 1×1/1.13 | 4.5 | 26.4 |
1×1.5(A) | 1×1/1.38 | 4.9 | 34.6 |
1×1.5(B) | 1×7/0.52 | 5.2 | 36.5 |
1×2.5(A) | 1×1/1.78 | 5.8 | 46.4 |
1×4(A) | 1×1/2.25 | 6.4 | 65.9 |
1×4(B) | 1×7/0.85 | 6.8 | 73.7 |
1×6(A) | 1×1/2.76 | 7.0 | 91.6 |
1×10 | 1×7/1.35 | 8.8 | 152.0 |
2×1.5(A) | 2×1/1.38 | 9.8 | 109 |
2×1.5(B) | 2×7/0.52 | 10.5 | 123 |
2×2.5(A) | 2×1/1.78 | 11.5 | 157 |
2×2.5(B) | 2×7/0.68 | 12.0 | 172 |
2×4(A) | 2×1/2.25 | 12.5 | 205 |
2×4(B) | 2×7/0.85 | 13.0 | 222 |
2×6(A) | 2×1/2.76 | 13.5 | 265 |
2×6(B) | 2×7/1.04 | 14.5 | 286 |
2×10 | 2×7/1.35 | 18.0 | 471 |
3×1.5(A) | 3×1/1.38 | 10.5 | 136 |
3×1.5(B) | 3×7/0.52 | 11.0 | 146 |
3×2.5(A) | 3×1/1.78 | 12.0 | 190 |
3×2.5(B) | 3×7/0.68 | 12.5 | 207 |
3×4(A) | 3×1/2.25 | 13.0 | 252 |
3×4(B) | 3×7/0.85 | 14.0 | 272 |
3×6(A) | 3×1/2.76 | 14.5 | 344 |
3×10 | 3×7/1.35 | 19.0 | 574 |
4×1.5(A) | 4×1/1.38 | 11.5 | 164 |
4×1.5(B) | 4×7/0.52 | 12.0 | 174 |
4×2.5(B) | 4×7/0.68 | 13.5 | 252 |
4×4(A) | 4×1/2.25 | 14.5 | 321 |
4×4(B) | 4×7/0.85 | 15.5 | 346 |
4×6(A) | 4×1/2.76 | 14.5 | 470 |
4×6(B) | 4×7/1.04 | 15.5 | 439 |
5×1.5(A) | 5×1/1.38 | 12.0 | 192 |
5×1.5(B) | 5×7/0.52 | 12.5 | 205 |
5×2.5(A) | 5×1/1.78 | 14.0 | 272 |
5×2.5(B) | 5×7/0.68 | 14.5 | 292 |
5×4(A) | 5×1/2.25 | 16.0 | 379 |
5×4(B) | 5×7/0.85 | 17.0 | 418 |
5×6(A) | 5×1/2.76 | 17.5 | 518 |
5×6(B) | 5×7/1.04 | 18.5 | 550 |
Code Name | Size (KCM) | Strand | Approx.EC Cond with Equivalent Resistance | Stranding | Diameter(in) | Cross Sectional Area (Sq in) | Weight per 1000ft (lbs) | Rated Strength (lbs) | Resistance Ohms/1000ft (lbs) | ||
Individual Wires | Complete Cable | DC @ 20ºC | AC@ 75ºC | ||||||||
Akron | 30.58 | 7/w | 6 | 6/1 | .0661 | .198 | .0240 | 28.7 | 1,110 | .659 | .785 |
Alton | 48.69 | 7/w | 4 | 6/1 | .0834 | .250 | .0382 | 45.7 | 1,760 | .414 | .493 |
Ames | 77.47 | 7/w | 2 | 6/1 | .1052 | .316 | .0608 | 72.7 | 2,800 | .260 | .310 |
Azusa | 123.3 | 7/w | 1/0 | 6/1 | .1327 | .398 | .0968 | 115.7 | 4,460 | .163 | .195 |
Anaheim | 155.4 | 7/w | 2/0 | 6/1 | .1490 | .447 | .1221 | 145.9 | 5,390 | .130 | .154 |
Amherst | 195.7 | 7/w | 3/0 | 6/1 | .1672 | .502 | .1537 | 183.7 | 6,790 | .103 | .123 |
Alliance | 246.9 | 7/w | 4/0 | 6/1 | .1878 | .563 | .1939 | 231.8 | 8,560 | .0816 | .0973 |
Butte | 312.8 | 19/w | 266.8 | 26/7 | .1283 | .642 | .2456 | 293.6 | 11,000 | .0644 | .0769 |
Canton | 394.5 | 19/w | 336.4 | 26/7 | .1441 | .721 | .3098 | 370.3 | 13,300 | .0511 | .0610 |
Cairo | 465.4 | 19/w | 397.5 | 26/7 | .1565 | .783 | .3655 | 436.9 | 15,600 | .0433 | .0518 |
Darien | 559.5 | 19/w | 477.0 | 26/7 | .1716 | .858 | .4394 | 525.5 | 18,800 | .0360 | .0431 |
Elgin | 652.4 | 19/w | 556.5 | 26/7 | .1853 | .927 | .5124 | 612.4 | 21,900 | .0309 | .0371 |
Flint | 740.8 | 37/w | 636.0 | 26/7 | .1415 | .991 | .5818 | 695.5 | 24,400 | .0272 | .0327 |
Greely | 927.2 | 37/w | 795.0 | 26/7 | .1583 | 1.108 | .7282 | 870.4 | 30,500 | .0217 | .0263 |
Code Name | Size | No./Dia.of Stranding Wires | Approx. Overall Dia. | Approx. Weight | Code Name | Size | No./Dia.of Stranding Wires | Approx. Overall Dia. | Approx. Weight | ||
AWG or MGM | Alum. | ST. | AWG or MGM | Alum. | ST. | ||||||
No./mm | No./mm | mm | kg/km | No./mm | No./mm | mm | kg/km | ||||
Swanate | 4 | 7/1.96 | 1/2.61 | 6.53 | 93 | Tern | 795 | 45/3.38 | 7/2.25 | 27.03 | 1300 |
Sparrow | 2 | 6/2.67 | 1/2.67 | 8.01 | 129 | Condor | 795 | 54/3.08 | 7/3.08 | 27.72 | 1461 |
Sparate | 2 | 7/2.47 | 1/3.30 | 8.24 | 148 | Cuckoo | 795 | 24/4.62 | 7/3.08 | 27.74 | 1461 |
Robin | 1 | 6/3.00 | 1/3.00 | 9.00 | 163 | Drake | 795 | 26/4.44 | 7/3.45 | 28.11 | 1550 |
Raven | 1/0 | 6/3.37 | 1/3.37 | 10.11 | 206 | Coot | 795 | 36/3.77 | 1/3.77 | 26.41 | 1184 |
Quail | 2/0 | 6/3.78 | 1/3.78 | 11.34 | 259 | Mallard | 795 | 30/4.14 | 19/2.48 | 28.96 | 1728 |
Pigeon | 3/0 | 6/4.25 | 1/4.25 | 12.75 | 327 | Ruddy | 900 | 45/3.59 | 7/2.40 | 28.73 | 1472 |
Penguin | 4/0 | 6/4.77 | 1/4.77 | 14.31 | 412 | Canary | 900 | 54/3.28 | 7/3.28 | 29.52 | 1554 |
Waxwing | 266.8 | 18/3.09 | 1/3.09 | 15.45 | 422 | Rail | 954 | 45/3.70 | 7/2.47 | 29.61 | 1560 |
Merlin | 336.4 | 18/3.47 | 1/3.47 | 17.35 | 532 | Catbird | 954 | 36/4.14 | 1/4.14 | 28.95 | 1421 |
Linnet | 336.4 | 26/2.89 | 7/2.25 | 18.31 | 656 | Cardinal | 954 | 54/3.38 | 7/3.38 | 30.42 | 1753 |
Oriole | 336.4 | 30/2.69 | 7/2.69 | 18.83 | 737 | Ortlan | 1033.5 | 45/3.85 | 7/2.57 | 30.81 | 1690 |
Chickadee | 397.5 | 18/3.77 | 1/3.77 | 18.85 | 629 | Tanager | 1033.5 | 36/4.30 | 1/4.30 | 30.12 | 1539 |
Ibis | 397.5 | 26/3.14 | 7/2.44 | 19.88 | 775 | Curlew | 1033.5 | 54/3.52 | 7/3.52 | 31.66 | 1900 |
Lark | 397.5 | 30/2.92 | 7/2.92 | 20.44 | 871 | Bluejay | 1113 | 45/4.00 | 7/2.66 | 31.86 | 1821 |
Pelican | 477 | 18/4.14 | 1/4.14 | 20.70 | 754 | Bunting | 1192.5 | 45/4.14 | 7/2.76 | 33.12 | 1949 |
Flicker | 477 | 24/3.58 | 7/2.39 | 21.49 | 877 | Grackle | 1192.5 | 54/3.77 | 19/2.27 | 33.97 | 2190 |
Hawk | 477 | 26/3.44 | 7/2.67 | 21.80 | 931 | Bittern | 1272 | 45/4.27 | 7/2.85 | 34.17 | 2080 |
Hen | 477 | 30/3.20 | 7/3.20 | 22.40 | 1044 | Pheasant | 1272 | 54/3.90 | 19/2.34 | 35.10 | 2335 |
Osprey | 556.5 | 18/4.47 | 1/4.47 | 22.35 | 880 | Skylark | 1272 | 36/4.78 | 1/4.78 | 33.42 | 1895 |
Parakeet | 556.5 | 24/3.87 | 7/2.58 | 23.22 | 1023 | Dipper | 1351.5 | 45/4.40 | 7/2.92 | 35.16 | 2210 |
Dove | 556.5 | 26/3.72 | 7/2.89 | 23.55 | 1085 | Martin | 1351.5 | 54/4.02 | 19/2.41 | 36.17 | 2481 |
Eagle | 556.5 | 30/3.46 | 7/3.46 | 24.21 | 1219 | Bobolink | 1431 | 45/4.53 | 7/3.02 | 36.24 | 2342 |
Peacock | 605 | 24/4.03 | 7/2.69 | 24.20 | 1112 | Plover | 1431 | 54/4.14 | 19/2.48 | 37.24 | 2628 |
Squab | 605 | 26/3.87 | 7/3.01 | 24.51 | 1180 | Nuthatch | 1510.5 | 45/4.65 | 7/3.10 | 37.20 | 2470 |
WoodDuck | 605 | 30/3.61 | 7/3.61 | 25.25 | 1325 | Parrot | 1510.5 | 54/4.25 | 19/2.55 | 38.25 | 2773 |
Kingbird | 636 | 18/4.78 | 1/4.78 | 23.88 | 1007 | Lapwing | 1590 | 45/4.77 | 7/3.18 | 38.16 | 2599 |
Aluminum Sectional Area | Stranding No. and Dia. | Approx. Overall Dia | Approx. Weight | Calculated Breaking Load | Calculated D C Resistance at 20oC | Code Name | ||
AWG | (mm2) | Al. | St. | (mm) | (kg/km) | (KN) | (Ω/km) | |
6 | 13.30 | 6/1.68 | 1/1.68 | 5.04 | 53.75 | 5,303 | 2.157 | Turkey |
4 | 21.18 | 6/2.12 | 1/2.12 | 6.36 | 85.57 | 8,302 | 1.335 | Swan |
4 | 21.12 | 7/1.96 | 1/2.61 | 6.53 | 99.56 | 10,642 | 1.352 | Swanate |
2 | 33.59 | 6/2.67 | 1/2.67 | 8.01 | 135.70 | 12,653 | 0.854 | Sparrow |
2 | 33.54 | 7/2.47 | 1/3.30 | 8.24 | 158.60 | 16,171 | 0.852 | Sparate |
1 | 42.41 | 6/3.00 | 1/3.00 | 9.00 | 171.40 | 15,852 | 0.676 | Robbin |
1/0 | 53.52 | 6/3.37 | 1/3.37 | 10.10 | 216.20 | 19,455 | 0.536 | Raven |
2/0 | 67.32 | 6/3.78 | 1/3.78 | 11.30 | 272.00 | 23,529 | 0.426 | Quail |
3/0 | 85.14 | 6/4.25 | 1/4.25 | 12.80 | 344.00 | 29,417 | 0.337 | Pigeon |
4/0 | 107.20 | 6/4.77 | 1/4.77 | 14.30 | 433.40 | 37,055 | 0.268 | Penguin |
266800 | 135.00 | 18/3.09 | 1/3.09 | 15.50 | 430.50 | 30,519 | 0.213 | Wax wing |
266800 | 134.90 | 26/2.57 | 7/2.00 | 16.30 | 545.40 | 26,403 | 0.214 | Partridge |
300000 | 152.20 | 26/2.73 | 7/2.12 | 17.30 | 614.60 | 56,410 | 0.190 | Ostrich |
336400 | 170.20 | 18/3.47 | 1/3.47 | 17.40 | 542.90 | 38,487 | 0.169 | Merlin |
336400 | 170.60 | 26/2.89 | 7/2.25 | 18.30 | 689.90 | 62,918 | 0.169 | Linnet |
336400 | 170.50 | 30/2.69 | 7/2.69 | 18.80 | 784.50 | 77,267 | 0.170 | Oriole |
397500 | 201.60 | 24/3.27 | 7/2.18 | 19.60 | 762.50 | 65,099 | 0.143 | Brant |
397500 | 201.30 | 26/3.14 | 7/2.44 | 19.90 | 813.50 | 72,426 | 0.143 | Ibis |
397500 | 200.90 | 30/2.92 | 7/2.92 | 20.40 | 924.40 | 90,485 | 0.144 | Lark |
477000 | 242.3 | 18/4.14 | 1/4.14 | 20.70 | 772.60 | 52,302 | 0.119 | Pelican |
477000 | 241.7 | 24/3.58 | 7/2.39 | 21.50 | 914.90 | 73,243 | 0.120 | Flicker |
477000 | 241.6 | 26/3.44 | 7/2.67 | 21.80 | 975.50 | 86,011 | 0.120 | Hawk |
477000 | 241.3 | 30/3.20 | 7/3.20 | 22.40 | 1,110.00 | 105,611 | 0.120 | Hen |
556500 | 282.4 | 18/4.47 | 1/4.47 | 22.40 | 900.70 | 60,972 | 0.120 | Osprey |
556500 | 282.2 | 24/3.87 | 7/2.58 | 23.2 | 1,068.00 | 84,424 | 0.1030 | Parakeet |
556500 | 282.6 | 26/3.72 | 7/2.89 | 23.6 | 1,142.00 | 100,838 | 0.1030 | Dove |
556500 | 282.1 | 30/3.46 | 7/3.46 | 24.2 | 1,298.00 | 123,470 | 0.1030 | Eagle |
605000 | 306.2 | 24/4.03 | 7/2.69 | 24.2 | 1,159.00 | 95,861 | 0.0948 | Peacock |
605000 | 307.2 | 26/3.87 | 7/3.01 | 24.5 | 1,236.00 | 108,317 | 0.0944 | Squab |
605000 | 307.2 | 30/3.61 | 7/3.61 | 25.3 | 1,414.00 | 128,736 | 0.0945 | Duck |
605000 | 307.2 | 30/3.61 | 19/2.16 | 25.2 | 1,398.00 | 133,082 | 0.0945 | Teal |
636000 | 323.1 | 18/4.78 | 1/4.78 | 23.9 | 1,031.00 | 69,722 | 0.0890 | Kingbirad |
636000 | 323.0 | 24/4.14 | 7/2.76 | 24.8 | 1,222.00 | 101,038 | 0.0894 | Rook |
636000 | 322.5 | 30/3.70 | 19/2.22 | 25.9 | 1,472.00 | 14,029 | 0.0897 | Egret |
666600 | 337.2 | 24/4.23 | 7/2.82 | 25.4 | 1,276.00 | 105,478 | 0.0856 | Flamingo |
666600 | 338.3 | 26/4.07 | 7/3.16 | 25.8 | 1,366.00 | 117,258 | 0.0854 | Gannet |
Type | Type | Name | No. of Cores | Nominal Cross-Section of Conductor(mm2) |
Cu Core | Al Core | 1 | 1.5--1000 | |
YJV (YJY) | YJLV (YJLY) | XLPE Insulated,PVC(PE) Sheathed Power Cable | 1 | 1.5--1000 |
YJV22 (YJV23) | YJLV22 (YJLY23) | XLPE Insulated,Steel Tape Armoured,PVC(PE) Sheathed Power Cable | 2/3/4/5 | 1.5--400 |
YJV32 (YJLV33) | YJLV32 (YJLY33) | XLPE Insulated,Fine Steel Wire Armoured,PVC(PE) Sheathed Power Cable | 2/3/4/5 | 1.5--400 |
YJV42 (YJLV43) | YJLV42 (YJLY43) | XLPE Insulated,Thick Steel Wire Armoured,PVC(PE) Sheathed Power Cable | 2/3/4/5 | 1.5--400 |
ZR-YJV (ZR-YJY) | ZR-YJLV (ZR-YJLY) | XLPE Insulated,PVC(PE) Sheathed Flame-retardant Power Cable | 2/3/4/5 | 1.5--400 |
ZR-YJV22 (ZR-YJY23) | ZR-YJLV22 (ZR-YJLY23) | XLPE Insulated,Steel Tape Armoured,PVC(PE) Sheathed Flame-retardant Power Cable | 2/3/4/5 | 1.5--400 |
ZR-YJV32 (ZR-YJY33) | ZR-YJLV32 (ZR-YJLY33) | XLPE Insulated,Fine Steel Wire Armoured,PVC(PE) Sheathed Flame-retardant Power Cable | 3+1/ 4+1/ 3+2 | 2.5--400 |
ZR-YJV42 (ZR-YJY43) | ZR-YJLV42 (ZR-YJLY43) | XLPE Insulated,Thick Steel Wire Armoured,PVC(PE) Sheathed Flame-retardant Power Cable | 3+1/ 4+1/ 3+2 | 2.5--400 |
1)3.6/6(7.2)kV,3.6/6.6(7.2)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable | |||||||||
No.X Nominal Cross Section of Conductor | Nominal Diameter of Conductor | Nominal Thickness of Insulation | Nominal Thickness of Copper Tape Screen | Nominal Thickness of Inner Sheath | Nominal Thickness of Steel Tape Armouring | Nominal Thickness of PVC Sheath | Approx. Overall Diameter | Approx. Weight | |
Al Conductor | Cu Conductor | ||||||||
No. X mm 2 | mm | mm | mm | mm | mm | mm | mm | kg/m | kg/m |
3 X 25 | 6 | 2.5 | 0.1 | 1.2 | 0.2 | 1.9 | 37.9 | 1.87 | 2.32 |
3 X 35 | 6.9 | 2.5 | 0.1 | 1.3 | 0.5 | 2 | 41.5 | 2.1 | 2.73 |
3 X50 | 8.2 | 2.5 | 0.1 | 1.3 | 0.5 | 2 | 44.3 | 2.37 | 3.22 |
3 X 70 | 9.7 | 2.5 | 0.1 | 1.4 | 0.5 | 2.1 | 47.9 | 2.77 | 4 |
3 X 95 | 11.3 | 2.5 | 0.1 | 1.4 | 0.5 | 2.2 | 51.6 | 3.21 | 4.91 |
3 X 120 | 12.8 | 2.5 | 0.1 | 1.5 | 0.5 | 2.4 | 55.4 | 3.69 | 5.84 |
3 X 150 | 14.2 | 2.5 | 0.1 | 1.5 | 0.5 | 2.5 | 58.6 | 4.15 | 6.85 |
3 X 185 | 15.9 | 2.5 | 0.1 | 1.5 | 0.5 | 2.6 | 62.5 | 4.73 | 8.11 |
3 X 240 | 18.3 | 2.6 | 0.1 | 1.6 | 0.5 | 2.7 | 68.5 | 5.62 | 10.05 |
3 X 300 | 20.4 | 2.8 | 0.1 | 1.7 | 0.5 | 2.9 | 74.5 | 6.55 | 12.11 |
3 X 400 | 23.2 | 3 | 0.1 | 1.9 | 0.8 | 3.2 | 83.6 | 8.78 | 15.86 |
3 X 500 | 26.4 | 3.2 | 0.1 | 2.1 | 0.8 | 3.4 | 93 | 10.52 | 18.85 |
2)6/10(12)kV,6.35/11(12)kV,,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable | |||||||||
No.X Nominal Cross Section of Conductor | Nominal Diameter of Conductor | Nominal Thickness of Insulation | Nominal Thickness of Copper Tape Screen | Nominal Thickness of Inner Sheath | Nominal Thickness of Steel Tape Armouring | Nominal Thickness of PVC Sheath | Approx. Overall Diameter | Approx. Weight | |
Al Conductor | Cu Conductor | ||||||||
No. X mm 2 | mm | mm | mm | mm | mm | mm | mm | kg/m | kg/m |
3 X 25 | 6 | 3.4 | 0.1 | 1.3 | 0.5 | 2 | 43.4 | 2.16 | 2.61 |
3 X 35 | 6.9 | 3.4 | 0.1 | 1.3 | 0.5 | 2 | 45.4 | 2.36 | 2.99 |
3 X50 | 8.2 | 3.4 | 0.1 | 1.4 | 0.5 | 2.2 | 48.8 | 2.69 | 3.54 |
3 X 70 | 9.7 | 3.4 | 0.1 | 1.5 | 0.5 | 2.3 | 52.4 | 3.1 | 4.33 |
3 X 95 | 11.3 | 3.4 | 0.1 | 1.5 | 0.5 | 2.4 | 56.1 | 3.56 | 5.26 |
3 X 120 | 12.8 | 3.4 | 0.1 | 1.5 | 0.5 | 2.5 | 59.5 | 4.04 | 6.19 |
3 X 150 | 14.2 | 3.4 | 0.1 | 1.5 | 0.5 | 2.6 | 62.7 | 4.49 | 7.19 |
3 X 185 | 15.9 | 3.4 | 0.1 | 1.6 | 0.5 | 2.6 | 66.6 | 5.12 | 8.49 |
3 X 240 | 18.3 | 3.4 | 0.1 | 1.7 | 0.5 | 2.8 | 72.4 | 5.99 | 10.42 |
3 X 300 | 20.4 | 3.4 | 0.1 | 1.8 | 0.5 | 3 | 77.5 | 6.86 | 12.42 |
3 X 400 | 23.2 | 3.4 | 0.1 | 1.9 | 0.8 | 3.2 | 85.4 | 8.97 | 16.05 |
3 X 500 | 26.4 | 3.4 | 0.1 | 2 | 0.8 | 3.4 | 93.7 | 10.65 | 19.5 |
3)8.7/10(15)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable | |||||||||
No.X Nominal Cross Section of Conductor | Nominal Diameter of Conductor | Nominal Thickness of Insulation | Nominal Thickness of Copper Tape Screen | Nominal Thickness of Inner Sheath | Nominal Thickness of Steel Tape Armouring | Nominal Thickness of PVC Sheath | Approx. Overall Diameter | Approx. Weight | |
Al Conductor | Cu Conductor | ||||||||
No. X mm 2 | mm | mm | mm | mm | mm | mm | mm | kg/m | kg/m |
3 X 25 | 6 | 4.5 | 0.1 | 1.4 | 0.5 | 2.1 | 48.6 | 2.53 | 2.98 |
3 X 35 | 6.9 | 4.5 | 0.1 | 1.4 | 0.5 | 2.2 | 50.7 | 2.76 | 3.39 |
3 X50 | 8.2 | 4.5 | 0.1 | 1.5 | 0.5 | 2.3 | 53.9 | 3.1 | 3.95 |
3 X 70 | 9.7 | 4.5 | 0.1 | 1.5 | 0.5 | 2.4 | 57.4 | 3.51 | 4.74 |
3 X 95 | 11.3 | 4.5 | 0.1 | 1.5 | 0.5 | 2.6 | 61.2 | 4.05 | 5.75 |
3 X 120 | 12.8 | 4.5 | 0.1 | 1.6 | 0.5 | 2.6 | 64.7 | 4.56 | 6.72 |
3 X 150 | 14.2 | 4.5 | 0.1 | 1.6 | 0.5 | 2.7 | 67.9 | 5.04 | 7.74 |
3 X 185 | 15.9 | 4.5 | 0.1 | 1.7 | 0.5 | 2.8 | 71.9 | 5.66 | 9.04 |
3 X 240 | 18.3 | 4.5 | 0.1 | 1.8 | 0.5 | 3 | 77.7 | 6.56 | 11 |
3 X 300 | 20.4 | 4.5 | 0.1 | 1.9 | 0.8 | 3.2 | 84.1 | 8.39 | 13.96 |
3 X 400 | 23.2 | 4.5 | 0.1 | 2 | 0.8 | 3.3 | 90.5 | 9.71 | 16.79 |
3 X 500 | 26.4 | 4.5 | 0.1 | 2.1 | 0.8 | 3.5 | 98.8 | 11.45 | 20.57 |
4)12/20(24)kV, 12.7/22(24)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable | |||||||||
No.X Nominal Cross Section of Conductor | Nominal Diameter of Conductor | Nominal Thickness of Insulation | Nominal Thickness of Copper Tape Screen | Nominal Thickness of Inner Sheath | Nominal Thickness of Steel Tape Armouring | Nominal Thickness of PVC Sheath | Approx. Overall Diameter | Approx. Weight | |
Al Conductor | Cu Conductor | ||||||||
No. X mm 2 | mm | mm | mm | mm | mm | mm | mm | kg/m | kg/m |
3 X 25 | |||||||||
3 X 35 | 6.9 | 5.5 | 0.1 | 1.5 | 0.5 | 2.4 | 55.6 | 3.14 | 3.77 |
3 X50 | 8.2 | 5.5 | 0.1 | 1.5 | 0.5 | 2.5 | 58.6 | 3.49 | 4.34 |
3 X 70 | 9.7 | 5.5 | 0.1 | 1.5 | 0.5 | 2.6 | 62.1 | 3.93 | 5.16 |
3 X 95 | 11.3 | 5.5 | 0.1 | 1.6 | 0.5 | 2.6 | 65.7 | 4.46 | 6.16 |
3 X 120 | 12.8 | 5.5 | 0.1 | 1.7 | 0.5 | 2.7 | 69.4 | 5 | 7.15 |
3 X 150 | 14.2 | 5.5 | 0.1 | 1.7 | 0.5 | 2.8 | 72.6 | 5.49 | 8.19 |
3 X 185 | 15.9 | 5.5 | 0.1 | 1.8 | 0.5 | 3 | 76.9 | 6.16 | 9.53 |
3 X 240 | 18.3 | 5.5 | 0.1 | 1.9 | 0.8 | 3.2 | 83.9 | 7.87 | 12.31 |
3 X 300 | 20.4 | 5.5 | 0.1 | 2 | 0.8 | 3.2 | 88.6 | 8.96 | 14.52 |
3 X 400 | 23.2 | 5.5 | 0.1 | 2.1 | 0.8 | 3.5 | 95.4 | 10.35 | 17.43 |
3 X 500 | 26.4 | 5.5 | 0.1 | 2.2 | 0.8 | 3.7 | 103.7 | 12.45 | 20.23 |
5)18/30(36)kV,19/33(36)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable | |||||||||
No.X Nominal Cross Section of Conductor | Nominal Diameter of Conductor | Nominal Thickness of Insulation | Nominal Thickness of Copper Tape Screen | Nominal Thickness of Inner Sheath | Nominal Thickness of Steel Tape Armouring | Nominal Thickness of PVC Sheath | Approx. Overall Diameter | Approx. Weight | |
Al Conductor | Cu Conductor | ||||||||
No. X mm 2 | mm | mm | mm | mm | mm | mm | mm | kg/m | kg/m |
3 X 25 | |||||||||
3 X 35 | |||||||||
3 X50 | 8.2 | 8 | 0.1 | 1.7 | 0.5 | 2.8 | 70.4 | 4.56 | 5.41 |
3 X 70 | 9.7 | 8 | 0.1 | 1.7 | 0.5 | 2.9 | 73.9 | 5.04 | 6.26 |
3 X 95 | 11.3 | 8 | 0.1 | 1.8 | 0.5 | 3 | 77.7 | 5.62 | 7.32 |
3 X 120 | 12.8 | 8 | 0.1 | 1.9 | 0.8 | 3.2 | 82.8 | 6.99 | 9.15 |
3 X 150 | 14.2 | 8 | 0.1 | 1.9 | 0.8 | 3.2 | 85.8 | 7.56 | 10.26 |
3 X 185 | 15.9 | 8 | 0.1 | 2 | 0.8 | 3.3 | 89.9 | 8.3 | 11.67 |
3 X 240 | 18.3 | 8 | 0.1 | 2.1 | 0.8 | 3.5 | 95.7 | 9.36 | 13.79 |
3 X 300 | 20.4 | 8 | 0.1 | 2.2 | 0.8 | 3.6 | 100.6 | 10.51 | 16.07 |
3 X 400 | 23.2 | 8 | 0.1 | 2.3 | 0.8 | 3.8 | 107.2 | 11.99 | 19.07 |
3 X 500 | 26.4 | 8 | 0.1 | 2.4 | 0.8 | 4 | 120.1 | 14.15 | 23.85 |
Type | Name | Section Area (mm2) | No.of Core | Application Site |
KVV | Copper Conductor,PVC Insulated and Sheathed Control Cable | 0.75 1.0 1.5 2.5 | 2-16 | Permanent installation indoors, in cable ditches or pipes |
4 6 | 2-14 | |||
10 | 2-10 | |||
KVVP | Copper Conductor PVC Insulated and Sheathed,Braiding Shielded Control Cable | 0.75 1.0 1.5 2.5 | 2-61 | Permanent installation indoors, in cable ditches or pipes where shielding is required |
4 6 | 2-14 | |||
10 | 2-10 | |||
KVVP2 | Copper Conductor PVC Insulated and Sheathed,Copper-tape Screened Control Cable | 0.75 1.0 1.5 2.5 | 4-10 | Permanent installation indoors,i n cable ditches or pipes where shielding is required |
4 6 | 7-61 | |||
10 | 4-10 | |||
KVV22 | Copper Conductor PVC Insulated and Sheathed,Steel tape Armored Control Cable | 0.75 1.0 1.5 2.5 | 7-61 | Permanent installation indoors, in cable ditches,Be able to withstand stronger external mechanical force |
4 6 | 4-14 | |||
10 | 4-14 | |||
KVVR | Copper Conductor PVC Insulated and Sheathed,Flexible Control Cable | 0.5-2.5 | 4-61 | Installation indoors where flexibility and movability are required |
KVVRP | Copper Conductor PVC Insulated and Sheathed,Braiding shielded Flexible Control Cable | 0.5 0.75 1.0 | 4-61 | Installation indoors where flexibility shielding and movability are required |
1.5 2.5 | 4-48 | |||
KYJV | CopperConductor XLPE Insulated and PVC Sheathed Control Cable | 0.75 1.0 1.5 2.5 | 2-16 | Permanent installation indoors, in cable ditches or pipes |
4 6 | 2-14 | |||
10 | 2-10 | |||
KYJVP | Copper Conductor XLPE Insulated,Braiding Shielded,PVC Sheathed Control Cable | 0.75 1.0 1.5 2.5 | 2-61 | Permanent installation indoors, in cable ditches or pipes where shielding is required |
4 6 | 2-14 | |||
10 | 2-10 | |||
KYJV22 | CopperConductor,XLPE Insulated,Steel-tape Armoured,PVCSheathed Control Cable | 0.75 1.0 1.5 2.5 | 7-61 | Permanent installation indoors, in cable ditches,pipes or underground Be cable to with stand stronger external mechanical force |
4 6 | 4-14 | |||
10 | 4-10 | |||
KYJVP2 | CopperConductor,XLPE Insulated,Copper tape Screened,PVCSheathed Control Cable | 0.75 1.0 1.5 2.5 | 7-61 | Permanent installation indoors, in cable ditches or pipes where shielding is required |
4 6 | 4-14 | |||
10 | 4-10 | |||
KYJVR | CopperConductor,XLPE Insulated,PVCSheathed Flexible Control Cable | 0.5-2.5 | 4-61 | Installation indoors where flexibility and movability are required |
KYJVRP | CopperConductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Flexible Control Cable | 0.5 0.75 1.0 | 4-61 | |
1.5 2.5 | 4-48 | Installation indoors where flexibility shielding and movability are required |
ASTM 600/1000v | |||||||||||
Core | AWG | Structure Size (mm) | Copper cable (kg/km) | ||||||||
Conductor | Insulation | Concentric conductor | Outer sheath | ||||||||
Single wire | XLPE | Single wire | UV-PVC | ||||||||
No. | Dia. | Thick | No. | Dia. | Thick | Dia. | |||||
1 | 16 | 7 | 0.49 | 1.14 | 39 | 0.321 | 1.14 | 6.82 | 81.46 | ||
1 | 10 | 7 | 0.98 | 1.14 | 34 | 0.511 | 1.14 | 8.67 | 172.04 | ||
1 | 8 | 7 | 1.23 | 1.14 | 25 | 0.643 | 1.14 | 9.68 | 221.58 | ||
1 | 6 | 7 | 1.55 | 1.14 | 25 | 0.813 | 1.14 | 10.98 | 160.50 | ||
1 | 4 | 7 | 1.96 | 1.14 | 27 | 1.020 | 1.14 | 12.62 | 509.26 | ||
IEC 60502-1 IEC 60228 600/1000v | |||||||||||
Size (mm2) | Structure Size mm | Copper cable (kg/km) | |||||||||
Concuctor | Insulation | Concentric conductor | Outer sheath | ||||||||
Single wire | Dia. | PVC | Single wire | UV-PVC | |||||||
No. | Dia. | Thick | No. | Dia. | Thick | Dia. | (kg/km) | ||||
10 | 7 | 1.35 | 4.05 | 1.55 | 20 | 0.85 | 1.4 | 11.79 | 301.55 | ||
16 | 7 | 1.7 | 5.1 | 1.55 | 32 | 0.85 | 1.4 | 12.84 | 431.7 | ||
25 | 7 | 2.14 | 6.42 | 1.6 | 29 | 1.13 | 1.5 | 15.02 | 647.46 | ||
Aluminum Cable | |||||||||||
16 | 7 | 1.7 | 5.1 | 1.55 | 26 | 1.13 | 1.4 | 13.42 | 244.16 | ||
25 | 7 | 2.14 | 6.42 | 1.6 | 29 | 1.13 | 1.5 | 15.02 | 307.3 | ||
35 | 19 | 1.53 | 7.65 | 1.65 | 27 | 1.35 | 1.6 | 16.99 | 390.15 |