* Suitable platform weighing,bed weighing,etc.
Maximum capacity(Emax) | 1.0t |
Accuracy class | C3 |
Approvals | OIML R60 C3 |
Maximum number of load cell intervals(nLC) | 3000 |
Ratio of minimum LC verification interval Y=Emax/Vmin | 10000 |
Combined error | ±0.020%FS |
Creep | ±0.016%FS/30min |
Temperature effect on sensitivity | ±0.011%FS/10ºC |
Temperature effect on zero | ±0.015%FS/10ºC |
Output sensitivity(=FS) | 3±0.003 mV/V 2.0±0.002 mV/V |
Input resistance | 350±3.5 Ω |
Onput resistance | 350±3.5 Ω |
Insulation resistance | ≥5000MΩ(50VDC) |
Zero balance | ±1.0%FS |
Compensated temperature | -10ºC~+40ºC |
Operating temperature | -35ºC~+70ºC |
Excitation,recommended voltage | 5V~12V(DC) |
Excitation maximum | 18V(DC) |
Safe overload | 150%FS |
Ultimate overload | 300%FS |
Recommended torque on fixation | M12: 100N.m; M18: 200N.m; M24: 700N.m |
Ingress protection(according to EN 60529) | IP67 |
ATEX classification(optional) | operating temperature: -20ºC~+40ºC |
II1G Ex ia II1C T4 | II1D Ex iaD20 T73ºC | II3G Ex nL II C T4 |
"S1" output sensitivity is 2.0±0.002MV/V |