Welcome to visit

Module spare parts HONEYWELL 05701-A-0550

Product Details

Product Details

Product Description

Product Description
Focus on DCS, PLC, robot control system and large servo system.
Main products: various modules / cards, controllers, touch screens, servo drivers.
Advantages: supply of imported original products, professional production parts,
Fast delivery, accurate delivery time,
The main brands include ABB Bailey, Ge / fuanc, Foxboro, Invensys Triconex, Bently, A-B Rockwell, Emerson, ovation, Motorola, xyvom, Honeywell, Rexroth, KUKA, Ni, Deif, Yokogawa, Woodward, Ryan, Schneider, Yaskawa, Moog, prosoft and other brands
HONEYWELL 05701-A-0550
The measure mode is the mode of operation upon transmitter power up and is the normal operating state of the transmitter. In this mode, the PV, output state, fault condition state, spike state, and secondary display information are displayed. All other modes of operation and fault information are accessible from the measure mode. BOREDOM SWITCH When any operating mode or state is entered and the measure mode is not returned to after the final step, the transmitter automatically returns to the measure mode of operation after 20 minutes of unattended use. PRIMARY DISPLAY The primary display shows the PV. The value of this variable is dependent on the configured analyzer, temperature compensation type, temperature value, sensor output, and damping value. The engineering units for the PV are dependent only on the configured analyzer (Table 5-1). SECONDARY DISPLAY The secondary display has the ability to show a large array of information. Since the display area only has six characters, only one item can be shown at any given time. Typically, this region displays the process temperature in degrees Celsius. However, it can be changed to display the process temperature in degrees Fahrenheit, output current in milliamperes, sensor type, cell constant, conductivity value and solute name for a concentration analyzer, or firmware revision. Refer to Section 10 for more information. Fault Information Smart Key Fault information is only accessible from the measure mode of operation. It is interrogated through the FAULT info smart key. Table 5-1. Engineering Units Analyzer Type Engineering Unit Concentration parts per million (ppm), parts per billion (ppb), percent (%), user-defined Conductivity µS/cm, mS/cm MEASURE MODE SECONDARY DISPLAY 5 - 2 WTPEEUI520002A1 A fault condition causes the FAULT icon to blink and the FAULT info smart key to appear. These indicators continue to be present as long as the fault condition exists. When pressing the FAULT info smart key, the faults appear in a first in, first out (FIFO) order and the first fault condition is shown in the secondary display. A short text string followed by the fault code is shown sequentially. Depressing the FAULT info smart key progressively moves from one fault to the next until all faults have been shown. Once all faults have been cycled through, the FAULT icon no longer blinks but remains on until removal of all fault conditions. If a new fault condition is detected, the FAULT icon begins to blink to indicate the newly detected condition. For more information on fault conditions and codes, refer to Section 12 and its related procedures. Menu Smart Key The MENU smart key provides access to all other modes of operation. By pressing the MENU smart key, the transmitter moves from one mode of operation to the next. Visual feedback is provided in two manners: the mode indication arrow moves to the next mode, such as CALIBRATE, and the secondary display shows the text string representative of that mode, such as CALIBR. Access into the displayed mode of operation is allowed by pressing the SELECT smart key. The exit to MEASURE smart key provides an escape function to the measure mode. As seen in the screen flow diagram shown in Figure 5-1, pressing the MENU smart key when in the measure mode moves the transmitter into the calibrate mode. Once in the calibrate mode, pressing the exit to MEASURE smart key returns the transmitter back to the measure mode. Pressing the SELECT smart key moves the transmitter into the calibrate states of operation. Pressing the MENU smart key moves the transmitter to the output/hold mode. Use Figure 5-1 to identify the smart key assignments and the resulting a

>> 120V 24W Max String Light
>> Chinese Vertical Machining Centre Vmc650 3 Axis CNC Milling Machine Center
>> Disposable High Quality VAS Deferens for Pig Farm
>> 10 Inch Multi-Function Adjustable Speed Aluminum Sawing Machine Woodworking Tie Rod Miter Saw
>> New Arrival Modern Household Three-tier Cloth Drawers Storage Rack With Adjustable Foot
>> Aluminum Guide Pulley for Wire Drawing Machine Enamelling Machine
>> Vmd48mm 3axis Drilling Milling Machine Vertical Machine High Precision
>> Bulk Water Meter (WP-SDC-PLUS)
>> Atlas Airline Inflight Aircraft Airplane Service Half Catering Meal Food Trolley Cart
>> 24 KW 30 KVA Cummins Diesel Genset
>> 5133695, 5145708 Clutch Disc for Fiat Tractor
>> 6000-12000bph Automatic Spring Drinking Pure Water Juice Carbonated Drinks/Juice Liquid/Glass/Can Bottle Washing Filling Capping/Bottling Making Production Line
>> Sign Dowell LPG Raycus 1W 2kw 3W 6kw 8kw 30kw CNC Steell Plaatwerk Fiber Laser High Level
>> Advanced Metal Recycling Equipment for Custom Motorcycle Components
>> DC53 Mini Tire Sidewall Cutter for Fast and Precise Cuts
>> Pulsed Magnetic Therapy device repairs the barrier of relief of fatigue, improves erythrocyte aggregation&endocrine disorders
>> 4 inch pressure vessel shell filter 4040 glass fiber reinforced plastic membrane housing
>> Plastic Crusher for Crushing PE PP Flakes and Film
>> ALSTOM MAE99-04 DCS/PLC CONTROLLER IN STOCK
>> Compact and Reliable Mechanical spline drive shaft coupling