US$0.90
|
5,000 Pieces
(MOQ)
|
Basic Info.
Alarm Valve Type
Wet Alarm Valve
Automatically Opened and Closed Repeatedly
Can Automatically Opened and Closed
Open Fire Sprinkler System Type
Deluge System
Closed Fire Sprinkler System
Wet Fire Sprinkler System
Dry Alarm Valve Type
Differential Type
Wet Alarm Valve Structure
Seat Type
Alarm Valve Diameter
100mm
Nozzle Flow Coefficient
K5.6; K8.0: K11.2
Deluge Valve Type
Diaphragm Type
Product Name
K5.6; K8.0: K11.2 Fire Sprinkler
Connection
3/4′′; 1/2′′; Bsp/NPT
OEM
Workable, MOQ=5000PCS
Listings and Approvals
Cccf,ISO9001, ISO14001
Production Capacity
200000sets/Month
Product Description
Product Description K=5.6/8.0 FIRE SPRINKLER
A fire sprinkler or sprinkler head is the component of a fire sprinkler system that discharges water when the effects of a fire have been detected, such as when a predetermined temperature has been exceeded. Fire sprinklers are extensively used worldwide, with over 40 million sprinkler heads fitted each year. In buildings protected by properly designed and maintained fire sprinklers, over 99% of fires were controlled by fire sprinklers alone.
K=11.2 FIRE SPRINKLER
FOREDE Series FRD004/FRD005 11.2K Standard Response, Standard Coverage Upright and Pendent Sprinklers are automatic sprinklers of the frangible bulb type. They are standard response, spray sprinklers that produce a hemi-
spherical water distribution pattern below the deflector.
The 11.2 K-factor, FRD004/FRD005 Sprinklers were subjected to full-scale, high-piled storage fire tests to qualify their use in lieu of 5.6 or 8.0 K-factor standard spray sprinklers for the protection of high-piled storage.
Higher flow rates can be achieved at much lower pressures with the 11.2 K-factor, FRD004/FRD005 Sprinklers, making their use highly advantageous in high density applications, such as the protection of high-piled storage.
Chrome coatings can be used to extend the life of the brass components used in Series FRD004/FRD005 Sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmospheres. Although coated sprinklers have passed the standard corrosion tests of the applicable approval agencies, the testing is not representative of all possible corrosive atmospheres. Consequently, it is recommended that the end-user be consulted with respect to the suitability of these corrosion resistant coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. Specification K=5.6/8.0 FIRE SPRINKLER
| Model | FRD001 | FRD002 | FRD003 | FRD004 | FRD005 | FRD006 |
| Style | Pendent | Upright | Sidewall | Pendent | Upright | Sidewall |
| Response | Standard response | Quick response |
| Response Temp. | 68°C/155°F |
| Working Pressure | 1.2 MPa/12 bar |
| Normal Diameter | DN15; DN20 |
| Thread | BSP / NPT |
| K Factor | 80 @metric (5.6@US); 115 @metric (8.0@US) |
| Material | Brass frame,brass deflector,Glass bulb,Teflon (PTFE) plated metal sealing ring |
K=11.2 FIRE SPRINKLER TECHNICAL DATA
Physical Characteristics
Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . .Brass
Cap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Brass
Sealing Assembly Glass bulb 5mm. . . . . .Glass Compression Screw . . . . . . . . . . . . . . . . .Brass Deflector . . . . . . . . . . . . . . . . . . . . . . . . . .Brass Refer to TABLE A & TABLE B for additional technical data.
| TABLE A |
| MODEL | FRD004 |
| WORKING PRESSURE | 175 psi (12,1 bar) |
| CONNECTION | 3/4'' BSP (NPT OPTIONAL) |
| K-FACTOR | 11.2 GPM/psi½ (161,4 LPM/bar½) |
TEMPERATURE RATING | 155 ºF (68 ºC) 200 ºF (93 ºC) 286 ºF (141 ºC) |
| INSTALLATION | Upright |
| TABLE B |
| MODEL | FRD005 |
| WORKING PRESSURE | 175 psi (12,1 bar) |
| CONNECTION | 3/4'' BSP (NPT OPTIONAL) |
| K-FACTOR | 11.2 GPM/psi½ (161,4 LPM/bar½) |
TEMPERATURE RATING | 155 ºF (68 ºC) 200 ºF (93 ºC) 286 ºF (141 ºC) |
| INSTALLATION | Pendent |
Packaging & Shipping
Order Information
Dear Customer,
Before ordering, please contact with our sales team to discuss order information.
If you have any other requirements or wanna know more info about our products, welcome to contact as well. Our Sales team and Technical Department are willing to support you.
>>
ZICAR Automatic MDF Edge Banding Machine Furniture Cabinet CNC EdgeBander Machine with Pre milling furniture manufacturing line
>>
0.9° 39hm2a34-064 Stepper Motor 2-Phase Hybrid Stepper Motor
>>
YFMC-720 A3 A4 A5 Hot and Cold Laminator Pouch Laminator Machine
>>
Veterinary animal husbandry freezer semen liquid nitrogen tank
>>
Customized Multi Cavity Pet Preform Injection Mold Hot Runner
>>
High Pressure Hydraulic Hose Crimping Machine CNC Digital Control 1/4-2" 4sh Hose
>>
Automatic Paper Cup Machine Price Paper Cup Forming Machine Paper Cup Making Machine Prices in India Pakistan
>>
LC200 Upgrade to LC300 2022 Facelifting Body Kit for Toyta Land Cruiser Landcruiser Bodykit 2008-2015 Bodykit
>>
Automatic Precision Computer Panel Saw CNC Woodworking Machine
>>
Customized Beans Hammer Mill Wood Chips Milling Machine Straw Crusher
>>
Handmade everlasting roses forever love
>>
Hydrolyzates Protein Silk Amino Acid 90% White Powder
>>
M30 Angle Bracket E10737
>>
2.5′′ Rope Pulley with Regular Straps (22cm) , Steel / Poultry Farm Equipment Components
>>
Tank Hydraulic Lifting Machine Jacks Hydraulic Jacking System
>>
Wind Generator Motor use Carbon Brush Holder
>>
Timing Chain for Mercedes-Benz M 103.940 M 103.942 M 103.980 M 103.984 M 103.987 TC1036
>>
Sinowoods E1 Commerical Laminate Flooring AC3 AC4 Laminate Floor for Home
>>
500MW Solar Panel Production Line Equipment
>>
Factory 36W/60W/80W/120W Waterproof LED Driver Power Supply 12V 24V DC Switching Adapter with GS UL TUV