| Main parameter: | ||
| Joint wall thickness: | 15~30mm | |
| Joint length: | 250~460mm | |
| Heating requirement: | Only heat drill pipe joint specified spot | |
| Heating length: | (100~150mm) | |
| Heating temperature: | 60℃-450℃ | |
| Heating time: | 15s-30s | |
| Heating mode: | · infiltrate preheating | |
| Electric parameter: | ||
| Medium-frequency power supply | 160KW | |
| Power supply frequency | 1000Hz | |
| Input current | 105 | |
| Input voltage | 3×380V 50Hz | |
| Output voltage | 750V | |
| General parameter: | ||
| Station number | 1 | |
| Inductor adjusting | Adjusting bracket fine-adjustment | |
| Inductor turns | Multiple turns | |
| Inductor specification | ф101.6~ф139.7)1set (ф152.4~ф177.8)1set (ф203~ф241)1set | |
| Cooling water flow | 15 m3/h | |
| Inflow temperature | 5~35℃ | |
| Outflow temperature | <55℃ | |