| NO. | Item | Standard | Note | |
| 1 | Standard Capacity | 40Ah | 2C (current value of 80A at 2C) | |
| 2 | Minimum Capacity | 40Ah | 2C | |
| 3 | Standard Voltage | 2.3 V | ||
| 4 | Dimension | D66*H161mm | ||
| 5 | Charge Conditions | Cut-off Voltage | 2.8±0.05V | constant-current charge to 2.8V at 10C, constant voltage charge to stop until 0.01C m A. |
| Cut-off Current | 0.01C | |||
| 6 | Max. Charging Current | 400A | ||
| 7 | Discharge Cut-off Voltage | 1.6V | ||
| 8 | Standard Discharge Current | 80A | ||
| 9 | Fast Discharge Current | 400A | This current is the maximum current recommended for the combination of cores, and the specific value should be determined according to the combination structure. | |
| 10 | Max. Continuous Discharge Current | 400A | Only for single cell | |
| 11 | Chemistry | LTO | ||
| 12 | Cycle Characteristic | the residual capacity is no less than 80% of rated capacity at 2C rate. | ||
| 39000 times(100%DOD) | ||||
| 13 | Working Temperature | Charge:-50℃~60℃ | |||||
| Discharge:-50℃~60℃ | |||||||
| 14 | Storage Temperature | -50℃~60℃ | Short-term storage ( | 15 | Cell Weight | Approx 1210g |