Factory Directly Sell the latest hybrid frequency pure sine wave inverter with built-in MPPT solar charger controller from 1KVA-10KVA .
Can support AGM del cycle battery ,Gel battery and Life PO4 battery .
Built-in controller can both offer MPPT and PWM for choice .
| MODEL | 1012 /24/48 | 1512 /24/48 | 2012 /24/48 | 3024 /48/96 | 5024 /48/96 | 6024/48/96 | 6524 /48/96 | 8048 /96/180 | 10048 /96/180 |
| Input | |
| Capacity (VA) | 1000VA | 1500VA | 2000VA | 3000VA | 5000VA | 6000VA | 6500VA | 8000VA | 10000VA |
| Voltage (DC) | 12/24/48V | 12/24/48V | 12/24/48V | 24/48/96V | 24/4 8/96V | 24/48/96V | 24/48/96V | 48/96/180V | 48/96/180V |
| Nominal Voltage | 220VAC/110VAC |
| Voltage Range | 154-265VAC/77-135VAC |
| Frequency | 50-60Hz Auto sensing |
| Output | |
| Watt | 800W | 1200W | 1800W | 2400W | 4000W | 4800W | 5200W | 6400W | 8000W |
| Voltage | 220VAC/110VAC |
| Frequency | 50/60Hz |
| Waveform | Pure sinewave |
| Transfer time(AC to DC) | <8ms |
| Transfer time(DC to AC) | <8ms |
| Output voltage regulation | 10%rms |
| Bypass Mode | Yes |
| Saver Mode | Yes |
| Efficiency | >98% |
| Protection | |
| Input Protection Output Protection | Circuit Breaker |
| Circuit Breaker |
| Battery | |
| Battery Type | AGM-Deep Cycle.GEL,Life PO4 |
| | Up to 500Ah |
| Charging current | 20/10A | 30/15/7A | 35/18/9A | 30/15/7A | 40/20/10A145/22/11A | 50/25/13A | 35/17/8A | 50/25/12A |
| Low Level disconnect(Selectable) | (10V or 10. 5V)xN N means the number of batteries in series |
| LCD Indicator status | Input AC,Output AC |
| Battery DC,Output Load |
| Alarm,Fault |
| Battery Charge Level |
| Output Frequency |
| LED Indicator status | AC Line ln:Green |
| InverterGreen |
| Charging: Yellow |
| Alarm:Red |
| Battery low alarm | battery light discharge 11.5V*N; battery load discharge 11.5V*N@load<20%; 11V*N@load>50% / 10.5V*N@load>50%; |
| Battery low recovery | battery light discharge 12V*N; battery load discharge 12V*N@load<20%;11.5V*N@load>50% I 11V*N@load>50%; |
| DC low voltage shutdown | battery light discharge 11V*N; battery load discharge 11V*N@load<20%; 10.5V*N@load>50% / 10V*N@load>50%; |
| DC high voltage alarm and fault | 16V*N |
| DC high voltage recovery | 15V*N |
| Alarm | |
| Low battery alarm | Audible alarm-1 beeping per second |
| Overioad alarm | Audible alarm-continuous beeping |
| Fault | Audible alarm-continuous beeping |
| Environment | |
| Temperature | 0-40 |
| Humidity | CO-95 %, Non condensing |
| Accoustic Noise(db) | >55dB |
| Dimension | |
| Size Lx Wx H (mm) | 470x335x210 | 650x335x201 |
| Packaging LxWx H (mm) | 546x392x260 | 665x399x324 |
| Weight(kg) | 12 | 16 | 17.5 | 18.5 | 19 | 22 | 26.5 | 30 | 38 |