Welcome to visit

High quality multistage adjustable residual current protective device for electrical fire and hirearchical protection

Product Description

Product Description
Products DescriptionASJ10-LD1A Residual Current RelayASJ Series Residual Current Relay ACREL ASJ Series of action relay of after-current, low-voltage circuit break or low-voltage contactor can be made up for combined after-current production device, which is mainly applied for the TT and TN system distributing circuit with the alternating current 50Hz, the rated voltage 400V or below.ASJ Series of action relay of after-current is applied in the earth fault protection for the electric circuit, so as to prevent the equipment damage and the fire accident of electric equipment caused by the ground fault current, moreover, it also can provide indirect contact protection against the electric shock risk.* The measurement of A-type after-current* The streamer display of current percentage;* The setting of rated residual action current* The setting of non-driving time of limitation* Two- pair relay output* Possessing the function of on-the-spot and long- distance testing and resetting* Frequency: 50Hz±5Hz* Auxiliary power supply: AC110V, AC220V, DC85 ~270V (permissible error±10%)* Consumption: ≤5WFrequency50Hz±5HzAuxiliary power supplyAC110V, AC220V, DC85 ~270V(permissible error ±10%)Consumption≤5WInstallationDin rail 35mmDimension(L*W*H)85*54*64mmTypes of ProductTypeFunctionInstallationASJ10-LD1CAC-type residual current measurement;Alarm prompt of current crossing line;Rated residual operating current can be measured;Limit non-driving time can be set;Two sets of relay output; With local and remote “test” and “reset” functions.Guide(DIN35mm)ASJ10-LD1AA-type residual current measurement;Current percentage light column display;Rated residual operating current can be measured;Limit non-driving time can be set;Two sets of relay output (settable)note 1; With local and remote “test” and “reset” functions.ASJ10L-LD1Anote2A-type residual current measurement;Rated residual operating current can be measured;Limit non-driving time can be set;Two sets of relay output (settable);Transformer breakage alarm can be set;Pre-alarm value can be set;Return value can be set.With on-site display, remote "test", "reset" LCD display, 25 event records.ASJ20-LD1CAC-type residual current measurement;Alarm prompt of current crossing line;Rated residual operating current can be measured;Limit non-driving time can be set;Two sets of relay output; With local and remote “test” and “reset” functions.Panel(48*48)ASJ20-LD1AA-type residual current measurement;Current percentage light column display;Rated residual operating current can be measured;Limit non-driving time can be set;Two sets of relay output (settable)note 1; With local and remote “test” and “reset” functions.Note 1: The function of setting for relay means that you can set the initialization and the output state of relay by yourself through the code dialing on the panel; the specific setting guide can be found from the chapter 5.2. Note 2: Optional function, RS485 interface, Modbus-RTU Communication, type is ASJ10L-LD1A/C.Technical ParameterTechnical ParameterIndicatorAC typeA typePower supplyVoltage rangeAC110V、AC220V(±10%)AC/DC85~265VPower dissipation≤5WInputRated residual operating current I△n0.03、0.1、0.3、0.5(A)0.03、0.05、0.1、0.3、0.5、1、3、5、10、30(A)note 3Limit non-driving time △t0.1、0.5(s)0、0.06、0.1、0.2、0.3、0.5、0.8、1、4、10(s)note 4Rated residual non-operating current I△no50%I△n50%I△nPerformance characteristicsSinusoidal ACSinusoidal AC and pulsating DCFrequency50Hz±5Hz50Hz±5HzOperating range-20% ~ -10%I△n-20% ~ -10%I△nOutputOutput modeOne is normally open and another is for transformationOne is normally closed or open, and another is for transformationContact capacity5A 250VAC5A 30VDCAL1:8A 250VAC; 5A 30VDCAL2:6A 250VAC; 5A 30VDCReset modeLocal reset or remote resetLocal reset, remote reset or automatic resetInstallation and use environmentTemperatureRun temperature:-20℃ ~ +55℃,Storage temperature:-30℃ ~ +70℃Humidity≤95%RH,no condensation, and no corrosive gas placesElevation≤2000mClass of pollutionGrade threeInstallation categoryType ⅢNote 3: ASJ10L-LD1A rated residual operating current IΔn is 10mA~30A continuously adjustable;Note 4: ASJ10L-LD1A limit non-driving time Δt is 0~10S continuously adjustable.Wiring IllustrationDimension & InstallationSolution StructureCertificationCompany ProfileFAQTitle goes here.Semi-Automatic PET Bottle Blowing Machine Bottle Making Machine Bottle Moulding MachinePET Bottle Making Machine is suitable for producing PET plastic containers and bottles in all shapes.

>> Modern aluminum waterproof exterior door french glass double swing doors price made in china
>> ASTM D1693 Pipe Samples Digital Axial Notch Milling Machine
>> Jnz High Quality 20mm Grey Color Outdoor Stone Tiles Outdoor Patio Floor Tiles
>> Natural bamboo wood sandwich ziplock reusable home food storage bags rack organizer with lid eco friendly 12 kitchen & tabletop
>> High Quality Outdoor Large Marquee Transparent PVC Wedding Clear Roof Party Event Tent
>> Make your own logo minimalist chronograph sport water resistant black diamond wristwatches women
>> Carbon Fiber W463 Hood for Mercedes G Class W463 Window Hood 2000-2021 Year
>> Agricultural Machinery Rotary Tiller of Tractor Mounted
>> Electric Mobility Scooter for Seniors Safe Waterproof Durable Battery
>> Export to Indonesia Hydraulic Guillotine Shear Machine
>> Diesel Level Sensor measurement instrument UTG21-H ultrasonic level probes level sensors
>> PE Plastic Shopping Bag Blown Film Machine Machine
>> Solar Hybrid Inverter off Grid Inverter DC to AC 240V 380V 30kVA Three Phase Pure Sine Wave Solar Power Inverter Work with Lithium Battery Power Pack
>> ISO 3801 Lab Round Fabric Sample Cutter
>> mini Handheld USB spray fan
>> OEM Custom High Quality White/Sand Gray Gra System Window
>> Good quality Electric Car Patrol control switch for Toyota CAMRY COROLLA TUNDRA LEXUS RAV4 MATRIX PRIUS OEM 84632 - 34011
>> Best Quality Pressurized Vacuum Tube Solar Water Heater for Home Rooftop Shower
>> 2022 New DIY SIP Broadcast Intercom Paging Door Phone Gateway Industrial Broadcast IP Paging System
>> Clothes Drying Rack; Wall-Mounted, Folding, Five Poles; L100cm