The short-circuit current at the terminals of an accumulator battery may be
supplied by the battery manufacturer, or may be calculated using the following
formula:
where:
• UMax is the maximum flashover voltage (no-load voltage);
• Ri
is the internal resistance of the elements forming the battery.
The internal resistance is usually supplied by the manufacturer, but may be
calculated from the discharge characteristics obtained through a test such as
detailed by IEC 60896 – 1 or IEC 60896 – 2.
For example, a battery of 12.84 V and internal resistance of 0.005 Ω gives a
short-circuit current at the terminals of 2568 A.
Under short-circuit conditions the current increases very rapidly in the initial
moments, reaches a peak and then decreases with the discharge voltage of
the battery. Naturally, this high value of the fault current causes intense heating
inside the battery, due to the internal resistance, and may lead to explosion.
Therefore it is very important to prevent and / or minimize short-circuit currents
in direct currents systems supplied by accumulator batteries.
Criteria for the selection of circuit-breakers
For the correct selection of a circuit-breaker for the protection of a direct current
network, the following factors must be considered:
1.the load current, according to which the size of the breaker and the setting
for the thermo-magnetic over-current release can be determined;
2.the rated plant voltage, according to which the number of poles to be
connected in series is determined, thus the breaking capacity of the device
can also be increased;
3.the prospective short-circuit current at the point of installation of the breaker
influencing the choice of the breaker;
4.the type of network, more specifically the type of earthing connection.
Note: in case of using of four pole circuit-breakers, the neutral must be at 100%

>> 4 Sides Galvanized Foldable Metal Roll Container Laundry
>> watch Adapter Restore Tool For Apple iWatch S1 S2 S3 S4 S5 S6
>> 38Galvanized Thickness Gauge|Galvanized layer thickness gauge|Galvanized online thickness gauge|Galvanized coating thickness detector
>> High-Quality Titanium CNC Machined Spare Parts at Affordable Prices
>> Double station translation magnetic polishing machine GG2380
>> SDS Max Chisel Bit Set for Masonry Drilling Flat Groove Point Alloy Steel
>> Shipping Forwarder, Air Freight and Courier From China to World
>> Grinder Spice Wheat Flour Milling Machine Molino De Maiz Moulin a Grain Corn Mill Machine with Prices
>> High-Quality One Year Roofing Roll Forming Machine for Corrugated Sheets
>> Hydroxyethyl Cellulose (HEC) for Paint
>> Red DOT & Laser Scope with 0 Maximum Output Power From Guangdong/China2.
>> Hot Sale Egg Chicken Farm Layer Poultry Battery Cages for Farms
>> Finn Power P20 Hose Pipe Pressing Portable Press Hydraulic Manual Crimping Machine
>> 80L 100L HDPE Drums Plastic Pallets Extrusion Blow Molding Machine
>> Tuya WiFi Video Door Phone 10.1 Inch Outdoor and 7 Inch Indoor Monitor Kit Security Doorbell Intercom IP System Access Control
>> Hot Sale for Colombia Market Rear hatch strut Gas spring for RIO
>> Mf833u1 Wireless Router DSL Router Modem Good Quality Wholesale Price
>> Taijia China factory price Concrete surface Resistivity tester Meter instrument for Resistivity and Concrete Quality Assessment
>> 4 inch reverse osmosis system 4040 Ro membrane filter housing
>> Ctzx32 Mini Drilling Milling Machine with 32mm Capacity From China with Dro