Module of PLC, DCS, ESD system card, the card is a vibration monitoring system, steam turbine control system module, the advantages of the gas generator spare parts brand: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts of our products are widely used in metallurgy, petroleum, glass, aluminum manufacturing, petrochemical industry, coal mine, papermaking, printing, textile printing and dyeing, mechanical, electronic manufacturing, automobile manufacturing, plastic machinery, electric power, water conservancy, water treatment/environmental protection, boiler heating, energy, power transmission and distribution and so on.
The Sequence can be restarted again by pressing the front panel YES key from the Sequence Status screen (screen 2), closing the Halt/Continue contact, or selecting Continue from a Modbus communications link. Table 5-3 lists the Auto Start status messages that may appear on the display and the meanings of each. MESSAGE 2 MEANING Disabled Auto Start Sequence is disabled Halted Sequence has been halted Mvg Low Idle Speed Setpt is moving to low idle At Low Idle Speed Setpt is holding at the low idle Setpt Mvg Hi Idle Speed Setpt is moving to high idle In Crit Band Setpt is moving through the critical avoidance band At High Idle Speed Setpt is holding at the high idle Setpt Mvg to Rated Speed Setpt is moving to rated Setpt Completed Auto Start Sequence is completed Table 5-3. Auto Start Messages The following Auto Start Sequence indications are available through the Modbus links: Setpt Moving to Min, Setpt at Low Idle, Ramping to High Idle, Setpt at High Idle, Turbine in Critical Speed Band, Ramping to Rated, and At Rated. In addition to these indications, the Low Idle Speed Setpoint, Low Idle Delay Time, Time Remaining at Low Idle, Low Idle to High Idle Rate, High Idle Speed Setpoint, High Idle Delay Time, Time Remaining at High Idle, High Idle to Rated Rate, Rated Speed Setpoint, Run Time (hours), and Hours Since Trip analog values are also available providing comprehensive sequence information. Direct Setpoint Entry The Speed setpoint can be directly set to a specific value, that is not within a critical speed avoidance band, using the ENTER key from the Speed Setpt screen (screen 4).
The messages that appear on the display are shown in Figure 5-5. There are limits on the range of the Speed setpoint that can be entered. The Speed setpoint must be below the maximum governor setting and above the idle setting. Once above minimum governor speed, the setpoint cannot be set below minimum governor. Also, if the unit is driving a generator and the unit is on-line, the speed setpoint cannot be set below the 3% minimum load setting (tunable in the Service Mode). The Speed setpoint can also be directly entered from either of the Modbus links, however, the allowed range is between the minimum and maximum governor speed settings. The allowed setpoint range is limited between the minimum load and the maximum governor settings if the unit is driving a generator and the unit is on-line. Both the speed setpoint and the Modbus Entered Speed setpoint are available over the communication link to provide feedback for directly entered Modbus values.

>> HC-S037 High quality full body first aid simulation/mannequin/Trauma Training Nursing Medical Manikin
>> Hydraulic Clamping Vertical Drill Press Z3025X7 China Universal Metal Radial Drilling Machine
>> TKUN High Resolution Touch Screen Monitor 1366*768 resistive touchscreen industrial monitor with HD VGA DC12-36V
>> Chain Bicycle Accessories Lock Bicycle Lock Key For Electric Car Anti Theft Cross Tooth Steel Wire
>> Waste Pet Bottle Recycling and Plastic Bottle Washing Plant
>> Heavy Duty Double Column CNC Gantry Type Machining Center Gmc2016 6000rmp Horizontal Milling Machine CNC Cutting/Drilling/Turning Machine
>> Summer long sleeved work suit for men with short sleeves, thin and wear-resistant, auto repair welding machine
>> 100t Per Day Rice Processing Complete Set Equipment Rice Milling Plant Rice Miller
>> High Quality Engineering Machinery Fuel Filter PU10461X FBO60329 MMH80990
>> USSE Sale Baby Fruit Feeder Food Grade Silicone BPA Free Toddler Baby Food Fresh Fruit Feeder
>> Mig-250 Igbt Inverter Co2 Mag Mma 220v Mig/mma 250 Mini Mig Welding Machine
>> Ctz16 CE Approval Pillar Vertical Drilling Machine for Metal Drilling
>> Weiqi Silicone Cups for Kids Toddler Training Drinking Cup
>> 20oz Car Mugs Double Wall Stainless Steel Thermal Vacuum Mug
>> High-Performance Drywall Stud Forming Machine for Efficient Construction
>> 50THV100M10X10.5 Rubycon Aluminum Electrolytic Capacitors - SMD HIGH TEMPERATURE ELECTROLYTIC CAPACITORS
>> Factory Outlet Environmental Carbonized Bamboo Floorartifical Style Strand Woven Bamboo Flooring
>> Party Decor Christmas Decorative Lighting Halloween Wedding Waterproof Outdoor IP65 Festival LED String Light Firecracker Light String
>> NE-25A medical patient bed three manual crank hospital bed with central control brake
>> Dual Heads Multilayer Digital Cutting Machine CNC Automated Fabric Cloth Synthetic Leather Cutter Machine