FPLC(Fast Liquid Chromatography) is the perferct choice for your protein /peptide/ Nucleotides purification task.
GoodSep FPLC 50 Modular system design, with a variety of options, can be flexibly applied to proteins and peptides, etc. purification of biomolecules. Software for intuitive and flexible method creation, system control and Result analysis. Compact and easy to move. Easy to operate with all functional components located on the front of the device. User-friendly intuitive software design, easy to operate and method editing. High-precision and large-flow plunger pump ensures a stable flow rate and gradient, which can cover a variety of small-scale, pilot-scale and small-scale production chromatography process. Accurate online detectors--fixed or variable wavelength UV detector, conductivity and pH, monitor and record various data of each run. Software with audit trail, user management, e-signature, data analysis and report functions to meet the 21 CFR part11 requirements.
| 1.1 | Biocompatibility gradient Piston pump,50ml pump PEEK Flow rate:0.001-50.000ml/min Accurange:1.2% Precision:0.5% Pressure range:0-10Mpa | 1 |
| |
| |
| |
| |
| 1.2 | Conductivity Detector Range:0.01-999.99mS/cm Accurancy:0.02mS/cm or 2% | 1 |
| | |
| | |
| 1.3 | PH Detector, Range:0-14 Accurancy:±0.1 pH unit with pH2 to 12 Flow cell volume:75ul | 1 |
| | |
| | |
| | |
| 1.4 | Sampling Valve with 1ml sample loop | 1set |
| | |
| 1.5 | DAD Detector wavelength :200-600nm Noise:±1*10-4Abs Optical path length:2mm wavelength accurancy ±1nm | 1 |
| | |
| | |
| | |
| | |
| 1.6 | Buffer inlet for A channel ,A1-A9 channels | 1set |
| | |
| 1.7 | 3 Columns Position valve,up/down flow /bypath | 2 sets |
| | |
| 1.8 | Buffer inlet for B channel ,B1-B9 channels | 1set |
| | |
| 1.9 | Outlet,1-9channels | 1set |
| | |
| 1.10 | Tempressure monitor unit, Online real-time system monitoring pressure to ensure system, chromatography and process safety; pressure range 0-10MPa (1500psi) | 1 |
| | |
| | |
| | |
| 1.11 | Mixer 2ml mixed cavity; electric mixing, mixing on the line, ensuring uniformity when the solution gradient is mixed; | 1 |
| | |
| | |
| 1.12 | Fraction collector with Fraction rack ,2ea,for 5ml/10ml/15ml faction | 1set |
| | |
| 1.13 | Jack for column | 1 |
| | |
| 2 | Extra Option Pump | |
| |
| 2.1 | Sample injection Piston pump,50ml pump PEEK Flow rate:0.001-50.000ml/min Accurange:1.2% Precision:0.5% Pressure range:0-10Mpa | 1 |
| |
| |
| |
| |
| 2.2 | Sampling inlet Valve with 9channels | 1 |
| |