Welcome to visit

Mains Power Hardwired Interlinked AC Smoke Fire Alarm DC 9V Battery Back up En14604 220V Smoke Detector

US$10.00
500-999 Pieces
US$9.00
1,000-2,999 Pieces
US$8.50
3,000-4,999 Pieces
US$8.00
5,000+ Pieces

Basic Info.

Model NO.
TSS890B-HI
Anti-Theft Alarm System Type
Smoke Alarms
Anti-Theft Alarm System-Wide
Wire Alarm Detectors
Anti-Theft Alarm System Distance
Common Detectors
Types of Smoke Detectors
Photoelectric Smoke Style
Infrared Sensor Probe Type
Inclination Sensor
Infrared Sensor Installation
Ceiling
Power Source
AC220V-AC240V, DC 9V Battery Backup
Size
140mm in Diameter X 44mm Depth
Certificate
CE, Bsi, Ukca, RoHS, Reach, ISO9001, BSCI
Transport Package
Carton
Specification
140mm in diameter x 44.9mm depth
Trademark
JBE
Origin
Zhejiang, China
Production Capacity
100000 Piece/Month

Product Description


AC 220V main power DC 9V backup battery with wired
interconnection photoelectric smoke alarm(wireless module optional)

Technical Specifications:
Power Source AC 220V-AC240V, DC 9Vbattery backup Alarm Volume >85dB(A) @ 3 meters
AC Quiescent Current < 100mA Low Voltage Threshold ≤7.5V
AC Alarm Current < 100mA Hush Time 8minutes
DC Quiescent Current < 10uA Product Service Life >10 years
DC Alarm Current < 28mA Humidity Range < 93% relative humidity (RH)
Alarm Sensitivity 0.10-0.16dB/m Temperature Range 0ºC to 40ºC
Comply With Standard EN14604:2005/AC:2008 Size 140mm in diameter x 44.9mm depth
Sound Pattern (BI 0.5s - pause 0.5s - BI 0.5s - pause 0.5s - BI 0.5s - pause 1.5s, with the RED LED flash, repeat this alarm pattern)

Details of the product function:
Standby mode after the product is installed, if the smoke alarm device operate properly, the red LED flashes once every 40 seconds
Local alarming mode when the smoke alarm device detect particles of combustion and the concentration of smoke reaches the alarm threshold, the red LED will flash once per second with pulsating alarm until the smoke is disappeared
Interconnection alarming mode when the smoke alarm device detect particles of combustion and the concentration of smoke reaches the alarm threshold, the alarm will send local alarm signal, other interconnection alarms will send alarm signals. The wired interconnection alarms will go into interconnection alarm mode: BI - BI - pause 1.2s, with the red LED flashes, this alarm pattern is repeated
Low battery mode when the battery voltage below threshold, the red LED will flash once every 40 seconds with a sound of "chrip"
Fault mode if the alarm detection signal decays below threshold, the alarm chirp occurs without LED flashes every 40 seconds
Silence mode press the test button at least 2 seconds, it will go into silence mode for approx 8 minutes. That will desensitize the alarm sensitivity temporarily. At this time, the red LED will flash once every 8 seconds
No disturb mode when the alarm device is in low battery mode, in order to avoid disturbing you at night, please press the test button for 3 seconds which will mute this warning tone for about 14 hours. After 14 hours, the warning tone will still go off. The red LED will flash once every 40 seconds during No disturb mode
Test mode test the unit to ensure proper operation by pressing the test button. At this time, the red LED will flash once per second with pulsating alarm until test button is released
NOTE WEEKLY TESTINGIS REQUIRED.

Wireless Interconnection Set up:
>1< Select one of smoke alarms as the MASTER unit. Treat other units as SLAVE units.
>2< Press the test button on the MASTER unit three times within two seconds, the red LED will flash quickly, the unit is now in sending radio signal mode. This mode will last for 48 seconds.
>3< While the MASTER unit is in sending radio signal mode, press the test button on any SLAVE unit three times within two seconds, the SLAVE unit learns this signal and completes the pairing after a sound "beep" with light flash once
>4< Repeat the above steps on all other SLAVE units
Clear wireless connection function Press the test button on any SLAVE unit three times within two seconds, the red LED will flash quickly, then press and hold the test button again until the red light goes out the first time and release the button immediately, the red LED will flash slowly, at this time, press the test button again, the SLAVE unit will beep 3 times, which means that the SLAVE unit clears wireless connected successfully.

>> Torsion Bar Synchronous Nc Press Brake Machine Kcn-50040
>> Use for Auto Repair Tool Bottle Jack Crane and Auto Parts Hydraulic Toe Jack 50ton Heavy Duty
>> 1500mm 2700mm 3000mm Knife Grinding Machine Knife Machine Tool Sharpener with CE
>> Finewire Platinum Spark Plugs Sp-411
>> 2024 High Precision Custom Made CNC Machining/Machined Aluminum Brass Parts OEM ODM Service Factory Price
>> Hot melt glue Textile laminating machine for Garment
>> Mechanic ROBOT Standard Edition 6560T-B11 Trinocular Stereo Microscope with 6.5-60X magnification
>> GSM-100e Temperature SMS Alarm Send Message to Your Phone Data Logger with External Sensor
>> Computerized Automatic Sewing Machine with Rotary Head for Car Upholstery
>> Plastic Injection Molding Custom Plastic Injection Molding Parts
>> Vtc80A High Speed Taiwan Hydraulic Turret CNC Vertical Lathe 800mm
>> Drilling Machine Cutting Machine CNC H Beam Drilling Machine
>> Taijia Integrated ferroscan concrete rebar detector rebar scanner locator Detect the position of rebar
>> almonde europe roasted california sugared candy coated whole almond bulk boxes
>> Full Automatic 2 Cavity Pet Blowing Machine Pet Plastic Bottle Making Machine
>> Kpu Shoes Upper Making Machine, PU Shoes Vamp Molding Pressing Making Kpu Sports Shoe Upper Machine
>> CE Approved Yc Ycl Series Single Phase Induction AC Capacitor Start Electric Motor
>> Factory Direct Sales with High-Quality and Low-Price Horizontal Tensile Testing Machine for Wire Rope
>> Factory price sterile soluble combat absorbent hemostatic gauze
>> CNC Loading and Unloading Soft and Hard Package Saw Blade Engraving Machine Cabinet Four Processes Plus Saw Blade Cutting Machine