Welcome to visit

Precise Measurement Acrel APM800/MA84 AC power analyzer three phase panel meter network multifunction ethernet energy meter Class 0.5S LCD display/with 8AI+4AO

Product Details

Product Details

Product Description

Product Description
General
APM series meters have full power measurement, energy statistics, analysis of power quality and network communications and other functions, are mainly used for comprehensive monitoring of the quality of power supply network.
Parameters
Technical Parameters
Index
Signal
Electrical network
Three-phase three-wire, three-phase four-wire, see the wiring diagram;
Frequency
45~65Hz;
Voltage
Rated value:AC 100V、110V、400V、690V;
Overload: 1.2 times rated value(continuous); 2 times rated value /1 second;
Power consumption:<0.5VA (per channel);
Current
Rated value: AC 1A, 5A, support 4 mm2 line access;
Overload: 1.2 times rated value(continuous); 10 times rated value/1 second;
Power consumption:<0.5VA (per channel);
Measurement accuracy
Voltage、current and power
class 0.5s/class 0.2s (APM800、APM810/APM801)
Active power
class 0.5s/class 0.2s (APM800、APM810/APM801)
Reactive power
class 2
Harmonic
1%(2rd~42nd)、2%(43rd~63rd)
Switch inputs
Dry contact inputs, built-in power supply;
Relay outputs
Contact type: open contact in main part, changeover contact in module;
Contact capacity:AC 250V/3A DC 30V/3A;
Pulse output of energy
Output mode: Optocoupler pulse with open collector;
Pulse constant:4000(5A)、8000(1A) imp/kWh;
Analog outputs
DC 0mA~20mA、4mA~20mA、0V~5V、1V~5V output, accuracy class 0.5%, load resistance ≤ 500Ω;
Analog inputs
DC 0mA~20mA、4mA~20mA、0V~5V、1V~5V iutput, accuracy class 0.5%
Storage card
Standard Capacity:4G,TF Card Up to 32G Capacity;
Communication
RS485 interface/Modbus-RTU protocol and DLT645 protocol
Profibus-DP interface/Profibus-DP protocol;
RJ45 interface (Ethernet) / Modbus-TCP, http, DHCP and other protocols;
Power supply
Working range: AC/DC 85V~265V or AC/DC 115~415V(P2);
Power consumption: Power consumption of the main part ≤ 15VA;
Safety
Power frequency withstand voltage
The power frequency withstand voltage between the shell and the auxiliary power supply, each input and output terminal group is AC 4kV/1min;
The power frequency withstand voltage between the auxiliary power supply and each input and each output terminal group is AC 2kV/1min;
The power frequency withstand voltage between the voltage input and other input/output terminal groups is AC 2kV/1min;
The power frequency withstand voltage between the current input and other input/output terminal groups is AC 2kV/1min;
The power frequency withstand voltage between the relay output and other input/output terminal groups is AC 2kV/1min;
The power frequency withstand voltage between each terminal group of switch input, communication, analog output and pulse output is AC 1kV/1min;
Insulation resistance
Inputs、outputs to the shell>100MΩ;
Electromagnetic compatibility
Meet IEC 61000 standard (Level 4);
Protection level
Display panel IP52
Environment
Operating temperature: -20 °C ~ +65 °C;
Storage temperature: -20°C~+70°C;
Relative humidity: ≤95% without condensation;
Altitude: ≤2500m;
Standards
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-30
Environmental Testing-Part 2-1:Tests Test A:Cold IDA
Part 2-1:Tests Test B:Dry heat
Part 2-30:Tests Test Db:Damp heat,cyclic(12+12h)
IEC 61000-4
Electromagnetic compatibility-Testing and measurement techniques
IEC 61557-12
Electrical safety in low voltage distribution system up to 1000V a.c. and1500V d.c –Equipment for testing,measuring or monitoring of protective measures- Part12:
Performances measuring and monitoring devices(PMD)
IEC 62053-22
Electricity metering equipment (a.c.)-Particular requirements - Part22:Static meter for active energy(class 0.2s and 0.5s)

Contact:
Overseas sales engineer: Dante Bao
email:dante.bao@email.acrel.cn
Mob:+86 18706163573(whatsapp/skype/wechat)

>> accessories ikada fishing rod guides sea boat dawa fishing rod genuine
>> Taijia sclerometer nondestructive evaluation ZC3-A concrete schmidt hammer rebound test hammer
>> SAFRAN (EATON) aircraft toggle switch 8869K6
>> Automatic Flatbed Laminator
>> Hollow Surface 2 Grade Cast Iron T Slot Table Machine Test Plate
>> Metal Sheet CNC Drilling Tapping Machine for Advanced Technology
>> Best Ce UL Saso Warm White 220V GS E26 8W SMD LED PAR Light for Indoor Lighting and Outdoor Lighting
>> Heavy Duty Flat Bed Big Bore CNC Lathe Machine with Swing Over Bed 1400mm Ck61140e 6ton
>> Hot Selling New Design Optic Fiber Splice Enclosure Distribution Box
>> Custom Size Fabric Trade Fair Display Environmental Fashion Exhibit Booth Design
>> Custom Casting Aluminum Accessories Power Line Parts
>> RG213 single braiding RF coaxial cable for antenna and telecommunication
>> Industrial Pallet Shredder for Wood, Plastic & Cardboard Recycling Heavy Duty Shredding Machine
>> Rexroth piston pump A10VSO100DRS32R-VPB12N00-S1439
>> Economic Electric Mechanical Round Duct Symmetrical Automatic 3 Three Slip Roll Roller Rolling Machine
>> Factory Price Pyrex Glass Sheet/Pyres Disc/Borofloat Glass Sheet/Borosilicate Glass Disc/Borosilicate Panel/Borosilicate Plate/Borosilicate Glass Sheet
>> Automotive Parts Rivet Push Type W204 Fender Liner Fastener Clips Retainer 0009905492
>> Advanced Honeycomb Cardboard Manufacturing Line for Industrial Applications
>> Made in China Fuse annunciator RX1-1000V for thermal power plant
>> TPR Lining Industrial Rubber Hose with Brass Aluminum Storz Coupling