| Model | SUN-6K-SG01HP3 -EU-AM2 | SUN-8K-SG01HP3 -EU-AM2 | SUN-10K-SG01HP3 -EU-AM2 | SUN-12K-SG01HP3 -EU-AM2 | SUN-15K-SG01HP3 -EU-AM2 | SUN-20K-SG01HP3 -EU-AM2 |
| Battery Input Data | ||||||
| Battery Type | Li-lon | |||||
| Battery Voltage Range (V) | 160-700 | |||||
| Max. Charging Current (A) | 37 | |||||
| Max. Discharging Current (A) | 37 | |||||
| Number of battery input | 1 | |||||
| Charging Strategy for Li-Ion Battery | Self-adaption to BMS | |||||
| PV String Input Data | ||||||
| Max. DC Input Power (W) | 7800 | 10400 | 13000 | 15600 | 19500 | 26000 |
| Max. DC Input Voltage (V) | 1000 | |||||
| Start-up Voltage (V) | 800 | |||||
| MPPT Range (V) | 150-850 | |||||
| Full Load DC Voltage Range (V) | 195-850 | 260-850 | 325-850 | 340-850 | 423-850 | 500-850 |
| Rated DC Input Voltage (V) | 600 | |||||
| PV Input Current (A) | 20+20 | 26+20 | 26+26 | |||
| Max. PV I (A) | 23+23 | 32+23 | 32+32 | |||
| No.of MPP Trackers | 2 | |||||
| No.of Strings per MPP Tracker | 1 | 2+1 | 2 | |||
| AC Output Data | ||||||
| Rated AC Output and UPS Power (W) | 6000 | 8000 | 10000 | 12000 | 15000 | 20000 |
| Max. AC Output Power (W) | 6600 | 8800 | 11000 | 13200 | 16500 | 22000 |
| AC Output Rated Current (A) | 9.1/8.1 | 12.2/11.6 | 15.2/14.5 | 18.2/17.4 | 22.8/21.8 | 30.3/29 |
| Max. AC Current (A) | 13 | 18 | 22 | 25 | 30 | 35 |
| Max. Continuous AC Passthrough (A) | 80 | |||||
| Peak Power (offff grid) | 1.5 time of rated power, 10 S | |||||
| Generator input/Smart load /AC couple current (A) | 9.1/80/9.1 | 12.2/80/12.2 | 15.2/80/15.2 | 18.2/80/18.2 | 22.8/80/22.8 | 30.3/80/30.3 |
| Power Factor | 0.8 leading to 0.8 lagging | |||||
| Output Frequency and Voltage | 50/60Hz; 3L/N/PE 220/380, 230/400Vac | |||||
| Grid Type | Three Phase | |||||
| DC injection current (mA) | <0.5%1n | |||||
| Efficiency | ||||||
| Max. Efficiency | 97.6% | |||||
| Euro Efficiency | 97% | |||||
| MPPT Efficiency | 98.9% | |||||
| Protection | ||||||
| Integrated | PV Input Lightning Protection, Anti-islanding Protection, PV String Input Reverse Polarity Protection, Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Output Shorted Protection, Surge protection | |||||
| Output Over Voltage Protection | DC Type II/AC Type III | |||||
| Certififications and Standards | ||||||
| Grid Regulation | EN50549, AS4777.2:2015, VDE0126-1-1, IEC61727, VDEN4105-2018, G99 | |||||
| Safety EMC / Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | |||||
| General Data | ||||||
| Operating Temperature Range (ºC) | -40~60ºC, >45ºC derating | |||||
| Cooling | Smart cooling | |||||
| Noise (dB) | <45 dB | |||||
| Communication with BMS | RS485; CAN | |||||
| Weight (kg) | 30.5 | |||||
| Size (mm) | 408W×638H×237D | |||||
| Protection Degree | IP65 | |||||
| Installation Style | Wall-mounted | |||||
| Warranty | 5 years | |||||