Welcome to visit

Acrel AMC72L-AV3 Programmable AC digital voltage meter/multifunction energy meter CE

Product Details

Product Details

Product Description

Product Description
General
AMC series AC ammeter&voltmeter, adopting AC sampling technology, can directly measure current and voltage of three phase grid. It can be used for local display, and connecting industrial control device to form measuring control system.
Function
Parameters
Technical Parameter
Value

Input
Rated Value
AC voltage:Single phaseAC 100V,400V
Three phaseAC 100V,400V,660V(UL-L,Only 72/ 96)
AC current:AC1A,5A;
DC voltage:1000V,300V,75mV,10V;
DC current: 0-20mA,4-20mA,5A;
Overload
Voltage: 1.2 times rated value(continuous); 2 times rated value /1 second
Current:1.2 times rated value(continuous); 10 times rated value /1 second
Frequency
45Hz~65Hz
Power Consumption
Power consumption of each voltage,current input circuit is less than 0.5VA
Accuracy
Class 0.5

Function
Display
LED or LCD
Communication
RS485,Modbus-RTU protocol;(1 start bit,8 data bit,1 stop bit,no parity)
Baud Rate 2400/4800/9600/19200 bps etc.
Alarm
1 channel passive relay,contact capacity 3A/30VDC,3A/250VAC, Used for high,low,unbalance alarm etc.
Analog
DC4~20mA,( loadSwitching
Input:4 channel or 2 channel dry contact Input,built in power supply
Output:2 channel switching output,NO relay contact,capacity:3A/30VDC,3A/250VAC
Auxiliary Supply
AC/DC 85-265V
Power Consumption
Insulation resistance
≥ 100MΩ
Power frequency withstand voltage
Between power supply set of terminals and signal input,output set of terminals 2kV/1min (RMS)
Between the shell and all set of terminals(except the set of terminals reference voltage less than 40V) AC 4kV

Environment
Temperature
Operation: -10℃~+55℃Storage: -25°C ~+70°C
Humidity
≤95%RH,no condensation,without corrosive gas
Altitude
≤ 2500m

FAQ
Q: No display on power?
A: Check whether the supply voltage is within the operating voltage range.
Q: Incorrect reading of voltage,current,electricty,etc?
A: Checking that the voltage/current ratio setting are correct;
Checking whether the wiring mode setting is consistent with the actual situation;
Checking whether the voltage transformer and current transformer are in good condition.
Q: Abnormal communication?
A: Check whether the adress,baud rate,check bits in the communication;
Setting are consistent with the host computer;
Check whether the RS485 converter is normal;
Check the connection is corrent if the resistor above 120 ohm is connected in parallel at the communication end.

>> Comfort Low Top Design Soft Leather Flat Shoe Women Work Shoe Casual Shoe
>> Ftl Mining Factory Efficiency Ore Rock Breaker Iron Plant Stone Cone Crusher
>> High Quality Activated Carbon Alkaline Water Purifier Pitcher
>> Cherry blossom Embroidery design
>> Atc 3 Axis Aluminum CNC Machining Center Drilling Milling Machine
>> 500W Stainless Steel Laser Welding Machine Handheld Laser Marking Machine for Metal
>> Width 600-900mm New Jwc Under Pad Production Line Making Machine
>> China Manufacturing Flexo Printing Plate Making Machine with Duraility and Quality Guarantee
>> AlunoTec Multifunctional Electric Pergola Curtains PVC Material Roller Manual Curtains Sunshade Windproof Zip Screen
>> Truck Forged or Casting Engine Parts Crankshaft for Isuzu 4HK1
>> Car washing system with tank fill with ion exchange resin pure water
>> NEW DESIGN bath mat TPE bath mat-tub mat shower mat
>> Used Hitachi Zx60 Mini Excavator Japan Second Hand Hitachi Mini Excavator Zx60
>> Ent Surgical Set Gap Cutter Burr Bone Shapers for Sale
>> Orange Juice Concentrate with High Quality
>> 200L Small Vacuum Emulsifying Mixer Shampoo Making Machine Cosmetic Cream Mixing Homogenizer Food Hygiene Grade Vacuum Mixing Equipment
>> Candy Kids Toothbrush with Macaron Colors
>> TIDEWAY LC0960-30 DOVETAIL BIT with bearing on shank
>> Fiber Laser Cutting Machine for Engraving Manganese Steel Metal Aluminum Copper Iron Sheet
>> exterior commercial solid wood glass french front doors for homes