| Measure accuracy | ±0.2%.±0.5% F.S | |
| Flow range | 0.3~15m/s | |
| Medium conductivity | >5μs/cm ;Water≥20μs/cm | |
| Ambient temperature: | -25℃~60℃ | |
| Working Pressure | ||
| DN 10~80mm | PN≤25Mpa | |
| DN 100~150mm | PN≤2.5Mpa | |
| DN 200~900mm | PN≤1Mpa | |
| DN 1000~2400mm | PN≤0.6Mpa | |
| Flow output signal | ||
| a. Main output | Current output: 0~10mA (Load resistance0~ 1.5KΩ), 4~20mA (Load resistance 0~750Ω) Pulse / frequency output: 1~5000Hz Communication output:MODBUS,RS-48,RS-232C,HART agreement, communication Interface has prevent from lightning effect. | |
| b. Control output | Upper limit alarm open circuit output of the collector (normal:0, alarm: 1) Lower limit alarm open circuit output of the collector (normal: 0, alarm: 1) Forward and reverse flow state open circuit output of the collector (forward: 0, reverse: 1) | |
| Supply voltage | AC220V or DC24V | |
| Instrument power | ≤ 20VA | |
| Language patterns: | Chinese and English (special order for the other languages) | |
| Sensor connection: | flanged, threaded connection, clamping connection type | |
| Explosion-proof levels | normal,flameproof(EIICT4-CT6), Intrinsically safety(ExiaII CT4) | |