|
US$200.00-220.00
|
1 Piece
(MOQ)
|
Basic Info.
Model NO.
JTG-ZF-C34/JTGB-UF-C35Ex
Anti-Theft Alarm System-Wide
Surface Control Alarm Detectors
Infrared Sensor Probe Type
Infrared Temperature Sensor
Infrared Sensor Installation
Embedded Wall
Flame Detector
UV+2-IR Sensor
Certification
Sil2,Cccf, CNAS, Ukas, Mc, ILAC-MRA
Transport Package
Standard Export Packing
Production Capacity
10000 PCS/Year
Product Description
JTG-ZF-C34/JTGB-UF-C35Ex Point Type UV & 2-IR Flame Detector(Dual Infrared & Single UV) Summary
JTG-ZF-C34/JTGB-UF-C35Ex point type UV & IR flame detector (hereinafter referred to detector) adopt flame multispectral signal acquisition method/full frequency wave analysis technology, it avoids the weaknesses to interference of traditional detectors. The detection environment is monitored by increasing slope signal detection technology (PAM), which improves the stability and sustainability of the detector. It ensures that the detector can quickly identify and detect fire while minimizing false alarm. The detector is suitable for all kinds of places, such as oil depot, wine depot, aircraft hangar, chemical equipment site, military equipment site, liquefied gas station, power station, tunnel, etc. With high anti-interference ability, can work well in indoor or outdoor environment.
The detector adopts six-wire connection style (two power lines, two fire touch spot lines, two fault touch spot lines), In case of alarm, the fire touch spot changes from normally open to normally closed. In case of fault alarm, the fault touch spot changes from normally closed to normally open. It can be connected with the fire alarm system of any manufactur
Technical Parameter Spectral response:190~260nm,1.0~1.7 um,2.1~3.2um . Response time:5~10s Monitoring angle:≤100° Working voltage: DC24V Static operating current: 45mA Alarm status current: 55mA Sensitivity: I class ~ class III, I class: 0-25m within the scope of the probe must be reported to the fire.
II class: 0-17 m within the scope of the probe must be reported to the fire.
III level: 0-12 m within the scope of the probe must be reported to the fire. Protection grade: IP66 Environment temperature: -10 ~ +55ºC Relative humidity: ≤93%RH(45±2ºC) Installation Angle: rotation Angle: 360°, elevation Angle: 90° Exd II CT6 Gb; Ex tD A21 IP66 T80ºC. Cable outlet thread: npt1/2 "nut explosion-proof hose is connected with outlet screw. Product size: Φ60×150mm.
Status Indicator Green: work indicator light, on when normal, internal device failure report green light does not work. Red: alarm indicator, normally off, often on fire. Power outages reset Output model Fire relay: normally open, close when alarming. Fault relay: normally closed, disconnected in case of fault Touch spot capacity: 3A /220VAC 3A /30VDC Use and Maintenance
Wiring: The wiring is shown in the picture. The red and black wires are connected to the positive and negative electrodes of the DC24V power supply. The yellow and white line is the contact output of the alarm relay, which closes when alarming. The green and blue line is the output of the fault relay, which is fault relay output, normally closed, fault disconnect. If module has terminal resistance, connect blue and green lines, yellow and white lines and terminal resistance, Resistance should be installed as close as possible to the detector. It is not recommended to install resistors near modules.
| Red | DC: +24V | Connect the controller to the power supplyDC24V |
| Black | DC: -24V |
| White | Fire relay touch spot output, dry contact normally open, closed in case of fire. | Connect the alarm module signal end |
| Yellow |
| Blue | Fault relay touch spot output, dry contact normal closure, fault disconnect. | After connecting the terminal resistance in series, it is connected to the signal end of the alarm module or to the module return route in series. |
| Green |
Installation Requirement Overlooking installation: Depression angle <45° Installation distance:The protection distance of detectors in oil sites is 3m ~ 5m. The protective space of chemical sites is 5m ~ 7m. The protection distance of smelting site is 7m ~ 10m. The protection spacing of power sites is 2m ~ 10m. There should be no obstacles blocking the line of sight of the detector in the fire area. If the obstacles cannot be avoided, the number of detectors should be considered to achieve no-dead Angle detection. Detector shell should be ground.
>>
Free Shipping Machinery Diesel Pig New Animal Feed Processing Food Feed Pellet Machine for Animal Poultry
>>
50000 Liters Propane Gas Storage Tank for LPG Station Plant 25 Tons LPG Bullet Storage Tank
>>
Dairy Farm Transparent Livestock Machinery Rolling Curtain PE Fabric
>>
Fabric Logo Embroidery Patch with Canada Logo
>>
MAICTOP car accessories car front grille for landcruiser prado fj150 2018-2021 bumper grille newest model
>>
good quality and price Poultry Slaughtering Machine Line for Chicken and Duck
>>
Mobile Wireless Charger, 3 in 1 Mobile Wireless Charging, Base Bracket for Wireless Charging, Type C Charger Station, Promotional Mobile Charger
>>
Frozen Foods Chaoshan Shrimp Ball
>>
LED Street Light Manufacturer Customized 160 Watt Street Lighting
>>
1.0630 H6XL-A00-0-M (R928005998) UTERS Replace Rexroth Hydraulic Filter element
>>
Powerful Knuckle Telescopic Boom Port Crane with High Lifting Capacity
>>
Fiber Laser Cutting Machine 120kw Laser Cutting Metal Machines
>>
Module spare parts NI SCXI-1100
>>
GE GasTurbine Card DS215GASQG4AZZ01A(DS200SDCCG4AFD+DS200SLCCG3ACC)
>>
Drilling Machine for Aluminum Window
>>
Aluminum Expanded Metal Roof Rain Collector Gutter Guard
>>
Premium Manufacturer Die Forging Tools Punch Set for Precision Crafting
>>
Clipsal Style 3 Push Button Light Electric Wall Switch Tempered Glass Faceplate
>>
Factory Sale Medium Duty Automatic Ck6180 CNC Lathe Machine Single Spindle Horizontal Lathe
>>
Waste Tyre Plastic Recycling Machinery Tire Crusher Production Line Rubber Crumb Grinding Machine Equipment Tire Shredder